Ads by Google
Wireless load cell GS204 has high precision, strong overload.
Technical Parameter:
Rated load | 5/10/20t |
Wireless Frequency | 240GHz |
Wireless Distance | Min:80m(Default)<200m optional> |
A/D Conversion Rate | ≥ 50times/ seconds |
Battary Life | ≥ 50 hours |
Sensitivity | (2.0±0.1%) mV/V |
Combined error | ±0.02% F.S |
Creep Error(30min) | ±0.02% F.S |
Zero balance | ±1% F.S |
Temp. effect on zero: | ±0.02% F.S/10°C |
Temp. effect on Span: | ±0.02% F.S/10°C |
Input resistance: | 750±5Ω |
Output resistance: | 702±2Ω |
Insulation resistance: | ≥5000MΩ |
Operating Temp. Range | -30~+70°C |
Maximum safe over load: | 120%F.S |
Ultimate over load: | 200%F.S |
Recommend excitation: | 10~12V DC |
Maximum excitation: | 15V DC |
Sealing Class: | IP65 |
Element material: | Alloy Steel, Stainless Steel |
Citation | GB/T7551-1997/ OIML R60 |