EDI ultra pure water treatment 1TPH
Running parameter
The product water quality of EDI is depended on the operation condition. Which including system designing data, feed water quality, feed water pressure. etc.
The EDI unit is adopted CP-3000S EDI module.
Voltage range: 50-180V
Current range: 0.5-6A
Product water flow rate: 1.0-2.0m3/r
Concentrate flow rate: 0.27-0.41m3/h
Electrolyte flow rate: 0.06m3/h
Running current and voltage
Warning: the heat produced when current pass through EDI module must be take away by water. Thus, once EDI product and concentrate stream is blocked or stopped, the power should be cut off. Otherwise, EDI module will be burned thoroughly.
feed water requirement
1)feed water: RO product water
2)TEA< 35ppm.
3) pH : 6.0-9.0
4) Temperature:5-35oC
5)Feed water pressure<0.4Mpa
6) hardness<10.0 ppm.
7) organic glass matter<0.5 ppm.
8) CL2<0.05 ppm , O3<0.02 ppm.
9) conductivity<60US/CM
10)H2S<0.01 ppm.
11)SIO2<0.5 ppm.
12)SDI15<1.0
13)color<5APHA
Pictures:
EDI ultra pure water treatment 1TPH