Ads by Google
DSY irrigation filter's datas:
Unit flow: 25-1200t/h, more flow can be done by more unit.
Minimum working pressure: 0.1MPa
Maximum working pressure: 1.6MPa, 2.5MPa 4.0MPa
Maximum working temperature: 70°C
Filtering degree: 100~5000 micron
Controlling way: pressure, time and manual operated
Cleaning time: 60s
Pressure loss when cleaning: :0.01MPa
Control voltage: 220V AC
Rated operational voltage: three-phase circuit 220V 380V 50Hz
Style | Line size(mm) | Filtering flow(t/h) | Filtering area(cm2) | Waste valve DN(mm) | One-time cleaning water quantity(kg) | Motor power (kw) | Weight(KG) | ||||||
DSY2 | 50 | 25 | 1500 | 25 | 60 | 0.09 | 65 | ||||||
DSY2.5 | 65 | 30 | 1500 | 25 | 60 | 0.09 | 70 | ||||||
DSY3 | 80 | 50 | 1500 | 25 | 60 | 0.09 | 75 | ||||||
DSY4 | 100 | 80 | 2750 | 25 | 60 | 0.18 | 108 | ||||||
DSY5 | 125 | 120 | 2750 | 40 | 150 | 0.18 | 126 | ||||||
DSY6 | 150 | 160 | 5780 | 40 | 150 | 0.18 | 166 | ||||||
DSY8 | 200 | 300 | 5780 | 40 | 150 | 0.18 | 180 | ||||||
DSY10 | 250 | 450 | 6000 | 50 | 200 | 0.37 | 328 | ||||||
DSY12 | 300 | 650 | 6000 | 50 | 200 | 0.37 | 338 | ||||||
DSY14 | 350 | 900 | 12000 | 65 | 350 | 0.55 | 692 | ||||||
DSY16 | 400 | 1200 | 12000 | 65 | 350 | 0.55 | 730 |
DSY-2.5 irrigation automatic cleaning screen filter