Product Detail
1.No arc discharge 2.High efficiency 3.Long lifespan and severe environment tolerance 4.Modular design

Features:No arc dischargeHigh efficiencyLong lifespan and severe environment toleranceModular design Advanced protection functionStrong overload abilityOutput precision (adjustable)Manual bypass function, automatic bypass can be customized

Specifications:

TECHNICAL PARAMETERS

Input

Nominal Voltage:                      

1 Phase: 110V/120V/127V or 220V/230V/240V                             3 Phase: 190V/200V/220V or 380V/400V/415V/440V

Input Voltage Range

+/-15%, +/- 30%, or customized

Nominal Frequency

50Hz or 60Hz

Frequency Range

+/- 5 Hz

Power factor

0.98

Output

Output Wave Form

sine wave

Nominal Voltage

1 Phase: 110V/120V/127V or 220V/230V/240V                             3 Phase: 190V/200V/220V or 380V/400V/415V/440V

Output Precision

+/- 2%   ( +/-2%~+/-15% adjustable)

Output Frequency

synchronized with input frequency

Harmonic distortion

< 3%

Respond Time

< 0.042 second

Efficiency

96% at full load

Indicator

Output Voltage

analog (voltmeter)

Output on

LED is lit

Output off

LED is lit

Output High Voltage

LED is lit

Output Low Voltage

LED is lit

Protection

Output High Voltage

output cutoff + LED is lit + buzzer beeping

Output Low Voltage

output cutoff + LED is lit + buzzer beeping

Open Phase

output cutoff + buzzer beeping

Overload

30s for 150%; 10s for 200%; out of range the output is cutoff

Surge

Optional, replaceable module

Short Circuit

Input cutoff by air breaker

Delay Output

6 seconds

Manual Bypass

yes

Automatic Bypass

Optional

Safety

Insulation Voltage

2000V 60S (coil to other body)

Insulation Resistance

>5MΩ (coil to ground)

Creepage Distance

> 8mm

Grounding Resistance

< 0.1 MΩ

No-load Loss

< 1%

Cooling Mode

forced cooling fan is activated when temperature is 100°C

Shock Resistant

0.3G

Temperature Rating of Coil

Class F, 155°C

Environment

Audible Noise

< 65dB (at 1 meter from cabinet with full load)

Operation Humidity

0%~95%, non-condensing

Operation Temperature

-10°C ~40°C

Operation Altitude

< 1000m

Storage Temperature

-20°C~ 40°C

MODEL NO., CAPACITY, RATED CURRENT, SIZE AND WEIGHT

3 Phase, +/-15% Input Range

Model No.

Rated Capacity

Rated Current

Machine Size

(W x D x H)

Weight

220V

380V

ARD-3010

10KVA / 8KW

26A

15A

28 x 38 x 62 cm

56 kgs

ARD-3015

15KVA / 12KW

39A

23A

66 kgs

ARD-3020

20KVA / 16KW

52A

30A

71 kgs

ARD-3030

30KVA / 24KW

78A

45A

32 x 40 x 73 cm

98 kgs

ARD-3045

45KVA / 36KW

118A

68A

36 x 46 x 82 cm

125 kgs

ARD-3060

60KVA / 48KW

158A

91A

145 kgs

ARD-3080

80KVA / 64KW

210A

121A

42 x 55 x 98 cm

179 kgs

ARD-3100

100KVA / 80KW

263A

152A

209 kgs

ARD-3120

120KVA / 96KW

315A

182A

50 x 65 x 120 cm

307 kgs

ARD-3150

150KVA / 120KW

394A

227A

347 kgs

3 Phase, +/-30% Input Range

Model No.

Rated Capacity

Rated Current

Machine Size

(W x D x H)

Weight

220V

380V

ARD-3010

10KVA / 8KW

26A

15A

35 x 45 x 79 cm

71 kgs

ARD-3015

15KVA / 12KW

39A

23A

39 x 47 x 50 cm

98 kgs

ARD-3020

20KVA / 16KW

52A

30A

43 x 53 x 98 cm

125 kgs

ARD-3030

30KVA / 24KW

78A

45A

145 kgs

ARD-3045

45KVA / 36KW

118A

68A

49 x 62 x 116 cm

179 kgs

ARD-3060

60KVA / 48KW

158A

91A

59 x 72 x 140 cm

307 kgs

ARD-3080

80KVA / 64KW

210A

121A

347 kgs

ARD-3100

100KVA / 80KW

263A

152A

62 x 86 x 192 cm

501 kgs

ARD-3120

120KVA / 96KW

315A

182A

601 kgs

ARD-3150

150KVA / 120KW

394A

227A

721 kgs