Specifications
1. pressure: 20000-200000psi 2. material:AA, BB, CC, DD, EE, FF 3. tempture: -46 to 121 (L U) 4. size: 2-1/16"~4-1/16"
1)WP:2000-15000psi 2)Nominal Bore:2-1/16"~4-1/16" 3)API 16C, API 6AChoke and kill manifold
1)An arrangement of piping or valves designed to control, distribute and often monitor fluid flow.
2)Manifolds are often configured for specific functions.
3)Choke manifold is necessary device to control the well kick successfully and execute the pressure control technology on oil/gas well in the course of drilling
Choke and kill manifold
It is the necessary device of controling overflow and blowout, enforcing oil and gas well pressure control technique. In the course of oil and gas well drilling, drilling fluid in the borehole is surely to be polluted by resident fluid, then the balance between hydrostatic fluid column pressure of drilling well fluid and reservoir pressure will be broken, causing overflow and blowout. When the polluted drilling fluid or hydraulic well whose pump performance is adjusted is cycled out so that the new balance can be achieved, the opening and close of choke valve to control back pressure so that the pressure of well bottom can be maintained in the situation of closing blowout preventer. Besides, Flexible choke&kill device can be used to clean well etc.
Application
Choke manifold is necessary device to control the well kick successfully and execute the pressure control technology on oil/gas well in the course of drilling, as it is, the device is adopted to execute new drilling-well’s technique of balance pressure, which can prevent the pollution of oil-layer, improve the speed of drilling and control blowout effectively. One end of the device connects with the side flange of BOP spool. When BOP closes, it can control the finite pressure from casing by adjusting the choke valve’s opening, so balanced drilling can work under minimum pressure-difference.
Specification and Structure
Choke manifold consists of choke valve, gate valve, pipeline,fittings and pressure gauge etc, see the above drawing and gate valve part and choke valve part. Pressure level is divided into five levels, i.e. 14MPa ,21MPa ,35MPa,70MPa,105MPa . It can be designed according to the requirement of customer.
Operating Requirement
1. All the working pressure of parts in choke manifold should be matched with the working pressure of the BOP stack used.
2. Choke manifold should be installed at the place where operator approach it conveniently, pressure test should be executed as installation, while the sealing test pressure should equal to the rated working pressure.
3.Pipeline should be so smooth and straight as possible, the corner of the pipeline should be made of 120°shaped forged steel bent pipe, which should have adequately large bore.
4. The working pressure gauge should be installed.
5. In winter, the choke manifold be able to work under a low temp condition.
Type | Working pressure (Mpa) (psi) | Nominal diameter (mm) (inch) | Bypass diameter (mm) (inch) |
YJX140 | 140Mpa (20000psi) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) |
YJX105 | 105Mpa (15000psi) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) |
YJX70C YJX70E | 70Mpa (10000psi) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) |
(Y)JX35 | 35Mpa (5000psi) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) |
(Y)JX21 | 21Mpa (3000psi) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) |
Kill Manifold
1. ApplicationIn case of increase in well head pressure, the kill manifold can provide a means of pumping heavy drilling fluid into the well to balance bottom hole pressure so that well kick and blowout can be prevented. In this case, by using blow down lines connected to the kill manifold, the increasing well head pressure also can be released directly for bottom hole pressure release, or water and extinguishing agent can be injected into the well by means of the kill manifold. The check valves on the kill manifold only allow injection of kill fluid or other fluids into the well bore through themselves, but do not allow any backflow so as to perform the kill operation or other operations.2. StructureThe kill manifold consists of check valves, gate vales, pressure gauges and pipelines. The one end of the kill manifold is connected to the drilling spool and the other end is connected to the pump. The kill manifold and choke manifold are both designed to API 16C and can be used together. The kill manifold is available from 14MPa, 21MPa, 35MPa and 70MPa pressure ratings.3. Operating Requirements(1) Working pressure of all pipelines, gate valves and check valves shall be compatible with that of the BOP stack used.(2) The kill manifold is not intended to be used as common lines for pouring drilling fluid.Type | Working pressure (Mpa) (psi) | Nominal diameter (mm) (inch) | Bypass diameter (mm) (inch) |
YGJX140 | 140Mpa (20000psi) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) | 78(3-1/16),65(2-9/16), 52(2-1/6) |
YGJX105 | 105Mpa (15000psi) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) | 78(3-1/16),65(2-9/16), 52(2-1/6) |
YGJX70 YGJX70A | 70Mpa (10000psi) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) |
YGJX35 | 35Mpa (5000psi) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) |
YGJX21 | 21Mpa (3000psi) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6) | 103(4-1/16),78(3-1/16), 65(2-9/16),52(2-1/6 |
Oilfield Kill Manifold and Choke Manifold