Welcome to ECOL - Join Free - Sign In
line interactive ups power supply manufactuer with AVR
line interactive ups power supply manufactuer with AVR
Supplier Info
[China Supplier]
Contact Person : Mr. Tian Tank
Tel : 0086-755-27151918
Fax : 0086-755-27151915
Product Detail
1.line interactive ups power supply 2.Input fuse 3.UPS with AVR and stablizer 4.Cold start 5.Surge protection

UPS systems, Uninterruptible power supply, UPS power supply with large power capacity ,Online UPS Features:

 

No breaks, SAI, USV, Uninterruptible power source

Including High frequency online ups :

1-10KVA( single phase in, single phase out)

10-20kVA(three phase in, single phase out)

 

High Frequency online UPS with output transformer:

 6-10kVA(single phase in, single phase out)    

10-20kVA(three phase in, single phase out)

 

High Frequency online telecom inverter 

 1-10kVA (single phase in, single phase out)

 

Line interactive UPS with AVR : 

 Compact 400-1000VA

 

1. Digital Design

Adopted DSP control technology and digital design topology, C UPS can be operated and maintained more conveniently.

 

2. Reversed Polarity N and L wire Detection Function.

Reversed Polarity of wiring or input protective grounding-wire is abnormal, at this point the indicators will alarm blink cyclically.

 

3. A Real Green-environmental Protection Power.

The commercial power input factor correction technique is used .Under the Normal mode, UPS achieves real energy-saving by inputting harmonic less than 10% and frequency power factor above 99%. 

 

4. Direct Current Cold Start Function     

When battery input voltage in the range of normal voltage. By pressing the ON button ,UPS can start up normally.

 

5. Alarm High-low Battery Input Voltage Protection Function

UPS alarms in case of the battery input voltage too high or too low. As the battery continuously  go up or down out of the normal range, UPS will alarm and stop input or transfer to bypass mode to ensure the battery life and protect user equipment

 

6. Communication and Monitoring Function

  Equipped with standard RS232 interface and intelligent slot (SNMP Slot). The UPS Operating and electrical parameters can be monitored through standard RS232. Through intelligent slot status interface the intelligent control can be flexibly configured according to different applications to users, for instance ,stem node, network monitoring, text message

 

7. Output High- Low Voltage Protection

When UPS output is greater than the output over-voltage protection point or less than the output low-voltage protection point, it will shut off inverter output to bypass  and automatically alarm .After all the fault removed, users can restart the machine normally.

 

8. Output  Short Circuit Protection

When the Inverter output overloaded and short circuit ,UPS will stop output and alarm and blink continuously. After the troubleshooting, it can restart normally.

 

9. Overloaded Protection Function

When Overload out of ranged load in certain time ,UPS will turn off the inverter and switch to Bypass output by alarming .After the load back to normal, UPS automatically transfer back to inverter output.

 

10. Over-temperature Protection

 

11. Intelligent Fan Speed Control Function

 According to load capability and environmental temperature

Model

Compact 400Compact 650Compact 1000VA
Capacity400 VA / 240 W650 VA / 390 W1000 VA /600 W
INPUT
Voltage110/120 VAC or 220/230/240 VAC
Voltage Range81-145 VAC / 162-290 VAC
Frequency Range60/50 Hz (auto sensing)
OUTPUT
AC Voltage Regulation (Batt. Mode)± 10%
Frequency Range (Batt. Mode)60 Hz or 50 Hz ± 1 Hz
Waveform (Batt. Mode)Simulated Sine Wave
Transfer TimeTypical 2-6 ms, 10ms max.
BATTERY
Battery Type & Number12 V/4.5 Ah x 112 V/7 Ah x 112 V/9 Ah x 1
Typical Recharge Time4-6 hours recover to 90% capacity
PROTECTION
Full ProtectionOverload, discharge, and overcharge protection
INDICATORS
LED Display 
AC ModeGreen lighting
Battery ModeGreen flashing
FaultN/A
ALARM
Battery ModeSounding every 10 seconds
Low BatterySounding every second
OverloadSounding every 0.5 second
Battery Replacement AlarmSounding every 2 seconds
FaultContinuously sounding
PHYSICAL
Dimension, D x W x H (mm)287 x 100 x 142
Net Weight (kgs)3.554.254.9
ENVIRONMENT
Humidity0-90 % RH @ 0- 40° C (non-condensing)
Noise LevelLess than 40dB
MANAGEMENT
Optional USB/RS-232 PortSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC