Electric power UPS
Using Standard Screen Cabinet with Power DesignZero-delay conversion between utility electric Supply / DC inverter power,inverter bypass ≤4msAC input,DC input and AC continuous output between complete isolationUsing DSP digital control technology, intelligent detection and monitoring capabilitiesHigh-speed IGBT drive inverterPassive monitoring of contacts and RS232/485
With overvoltage, low voltage, overcurrent, short circuit protection functions Big-screen English LCD display interface
Model | BUD220 -3050 | BUD220 -3100 | BUD220 -3150 | BUD220 -3300 | BUD220 -3500 | BUD220 -31000 | BUD220 -32000 | |||
DC input | Input rating voltage (VDC ) | 220 | ||||||||
Input rating current (A) | 25.3 | 49.4 | 74 | 148 | 247 | 494 | 988 | |||
Input DC voltage allowing range (VDC ) | 180 ~ 300 | |||||||||
AC input | Rating AC input voltage(VAC ) | 220( single-phase ) | 380 (three phase four wires) | |||||||
AC voltage allowing range( VAC ) | 220 ± 15% | 380 ± 15% | ||||||||
Input AC allowing frequency ( Hz ) | 45 ~ 60 | |||||||||
Power factor (PF) | 0.9 | |||||||||
Bypass input | Allowing input voltage range(VAC ) | 380 ± 15% (three phase four wires) | ||||||||
Input rating current(A) | 7.6 | 15.2 | 22.8 | 45.6 | 76 | 152 | 304 | |||
AC output | Rating capacity (KVA) | 5 | 10 | 15 | 30 | 50 | 100 | 200 | ||
Output rating power (KW) | 4 | 8 | 12 | 24 | 40 | 80 | 160 | |||
Output rating voltage and frequency | 380VAC , 50Hz (three phase four wires) | |||||||||
Output rating current (A) | 7.6 | 15.2 | 22.8 | 45.6 | 76 | 152 | 304 | |||
Output voltage precision (V) | 380 ± 3% | |||||||||
Output frequency precision (Hz) | 50 ± 0.05 | |||||||||
Waveform deviation factor (THD) ( liner load ) | ≤ 5% | |||||||||
Three-phase load unbalance ability | ≤ 100% | |||||||||
Dynamic response ( load 0 ←→ 100%) | 5% | |||||||||
Power factor (PF) | 0.8 | |||||||||
Load ability | 150%,10 seconds | |||||||||
Crest factor (CF) | 3:1 | |||||||||
Inverted efficiency (80% resistance load ) | 92% | |||||||||
Switchtime(ms) | AC DC screen | 0 | ||||||||
inverter bypass | 4 | |||||||||
Working environment | Insulation strength (input and output) | 2000V AC ,1 minute | ||||||||
Noise ( 1 meter) | ≤ 50dB | |||||||||
Using condition temperature | -10 °C ~+ 50 °C | |||||||||
humidity | 0~90%, no condensing | |||||||||
Using altitude (m) | ≤ 2000 | |||||||||
Machine dimension | width,depth,height(mm) | 550×485×1200 | 800×600×2260(or double screen) | 1000×800 × 2260(or double screen) | ||||||
Reference weight (KG) | 90 | 200 | 250 | 450 | 620 | 950 | 2300 | |||
Fault dry contact | Inverter abnormal,AC abnormal,battry abnormal,load abnormal,UPS abnormal | |||||||||
Protection function | Input reversing protection,input low-voltage protection,output over-load protection,output short-circuit protection, over-heat protection |