40kva three phase ups (3C3 Series)
The excellent performance:
1.IGBT based , high frequency rectifier and inverter design to achieve up to 93%-94% efficiency (Mains mode and battery mode),and low input current THD(>3%)
2. ECO mode to achieve up to 98% efficiency for energy saving.
3. Strong over load capability,10 minutes for 125% overload, and 1 minute for 150% overload.
4. wide input range which is suitable for very unstable power supply situation.
5. Generator input acceptable.
6. Power Factor Correction Achieve input PF 0.99.
High performance DSP processor
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output and reliability.
Flexible battery arrangement
Flexible arrangement of the amount of accumulators in each battery (32,30,or 28)can be achieved through the parameter resetting in the Centrio 3C3 series UPS, which effectively solves the question that the damage of some individual cell may influence the life of the whole battery until by eliminating the damaged ones from the unit in the process of using UPS.
N+X parallel redundancy (compatible to battery share in the parallel mode)
The maximum of the inbuilt parallel mode is 6 to 8 UPS without any other external accessories, which helps the customer to extend the system capacity with low cost. N stands for the minimum amount of UPS in the load and X stands for the amount of the redundant UPS in the system. The bigger the number of X is, the higher the reliability of the system.
The advanced controlling strategy is adopted to save the custom’s investment by sharing a battery until in the parallel redundancy mode.
Excellent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material with the diameter large than 12mm or the water drops) is achieved. If a higher protection level is required, the optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard the UPS’s security of operation in bad environment.
Technical specification
Product Series |
| Centrio 3C3 20-80KVA | ||||
Model |
| 3C3 20K | 3C3C 30K | 3C3 40K | 3C3 60K | 3C3 80K |
Capacity | VA/W | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW |
Input | Connection | 3-Phase + N + G | ||||
Rectifier Type | IGBT-based Controlled PFC | |||||
Input Voltage | 380(-45%~ +25%)VAC(when input voltage<75%, output power derating is required) | |||||
Input Frequency | 50 or 60 Hz (Accepted from 40 to 70Hz) | |||||
Input Current THD | 3% | |||||
Input Power Factor | ≥0.99 | |||||
Bypass Voltage | 380(-15%~ +15%)VAC | 380(-20%~ +15%)VAC | ||||
Output | Inverter Type | IGBT-based | ||||
Output Voltage | 380/400/415VAC | |||||
Output Frequency | 50Hz/60Hz±8%track bypass frequency input ;when input frequency exceeds ±8% or under the mode of battery power supply, frequency output should be±0.1%of nominal | |||||
Output Voltage THD | 1% (max) | |||||
Max.Load Crest Factor | 3:1 | |||||
Transient Volt.Resp | 10ms to recover ± 5% of Nominal Voltage for 0% to 100% or 100% to 0% step load | |||||
Max.Leading PF Load | Up to 0.9 | |||||
Overload Capability | ≥10min 110%<Load125% | |||||
≥1min 125%<Load150% | ||||||
Nominal battery voltage/Rated charging voltage | Battery Type | VRLA (Valve Regulated Lead Acid) | ||||
28 Pcs | ±168VDC/±189VDC | |||||
30 Pcs | ±180VDC/±202.5VDC | |||||
32 Pcs | ±192VDC/±216VDC | |||||
Efficiency | AC Mode | Up to 93% | Up to 94% | |||
Battery Mode | Up to 93% | Up to 94% | ||||
ECO Mode | Up to 98% | |||||
Operating Environment | Storage Temp | -25 to 55°C | ||||
Operating Temp | 0 to 40°C | |||||
Ambient Humidity | 0 to 95% (non_condensing) | |||||
Altitude | ≤1000m | |||||
Main unit | Dimension(W×D×H) mm | 420×643×956 | 470×710×1150 | 470×710×1150 | 600×800×1850 | 600×800×1850 |
Weight(Kg) | 82 | 110 | 114 | 282 | 306 |
Customer Feedback
Our R&D team have tested your UPS, they are satisfied with the performance of the sample. All the test
results are complying with the specification. We are highly appreciated it. --- N. Raja (from Chennai, India)
We are quite impressive with the IGBT function of this UPS. We are now trying to apply this model on our
telecommunication systems. --- Robert Alles (from Munich, Germany)
Order information
Trade term: FOB Shenzhen / Hongkong
Delivery time: 7-21 days after confirmed the order
Packaging Detail:Standard export carton or OEM package
Warranty
1 years since the date of purchase
Warranty term
1. Under the terms of this warranty, if failure occurs under normal usage within warranty period, Helior Technology will provide free maintenance based on the proof-documents.
2. If Failure or damage occurs due to incorrect operation, wire connection, or any other mis-opeartions, Helior Technology will provide pay maintenance on charge basis.
More detailed info for family UPS & Inverter, please do not hesitate to inquiry now!