Description:
Competitived price and high reliability 105°C Output capacitor AC input power suitable for the world High efficiency and low operation temperature Soft-start current can reduce the AC input impact effect With short-circuit and overload protection Compact size, light weight 100% full-load burn-in test Installed with EMI filter, minimum waveModel Performance | SMT-35-5 | SMT-35-12 | SMT-35-15 | SMT-35-24 |
DC output voltage | 5V | 12V | 15V | 24V |
Output Voltage Tolerance (Note 2) | ± 2% | ± 1% | ± 1% | ± 1% |
Rated output current | 7A | 3A | 2.4A | 1.5A |
Output Current Range | 0 -7A | 0 -3A | 0 -2.4A | 0 -1.5A |
Ripple and noise (Note 3) | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Into the line of stability (Note 4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability (Note 5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 35W | 36W | 36W | 36W |
Efficiency | 70% | 76% | 78% | 78% |
DC voltage adjustable range | ±10,-5% | ±10% | ±10% | ±10% |
Input Voltage Range | 85 ~ 132VAC/170 ~ 280VAC by switch 47-63Hz | |||
Input Current | 0.8A /115V ,0.4A /230V | |||
Inrush Current | Current 18A/115V 36A/230V cold start | |||
Leakage | <0.5mA/240VAC | |||
Overload Type | 105% ~ 150% Type: FOLDBACK cut output reset: Automatic restore | |||
Over Voltage Protection | …… ... ... | |||
Temperature Protection | …… ... ... | |||
Temperature Coefficient | ± 0.03%/ °C (0 ~ 50°C ) | |||
Start, rise, hold time | 200ms,100ms,30ms | |||
Earthquake resistance | 10 ~ 500Hz,2G 10min. / 1 cycle, duration 60 minutes, each axis | |||
Pressure of | Between input and output: 1.5KvAC, input and shell: 1.5KvAC, output and shell: 0.5KvAC | |||
Isolation Resistance | Input and output, input and shell, shell and output: 500VDC/100M Ohms | |||
Temperature, humidity | -10°C ~ + 60°C , 20% ~ 90% RH | |||
Storage temperature, temperature | -20°C ~ + 85°C ,10% ~ 95% RH | |||
Dimensions | 129*98*38mm | |||
Weight | 0.4Kgs | |||
Safety Standards | To meet UL1012 requirements | |||
EMC Standards | To meet the FCC PART15JCONDUCTION CLASS B | |||
Notes: 1 The above parameters test conditions are: 230VAC input, rated load, 25 °C 70% RH. Humidity. 2 Tolerance: includes set up tolerance, line stability, load stability (Note 5). 3 The ripple test: 20MHz with A12 "twisted pair, interrupted with 0.1uF & 47uF capacitor short-circuit. 4 Into the line voltage stability test: full load into the line of the minimum voltage to maximum voltage. 5 Load stability test: the load from 0% to 100%. |