Ads by Google
Optical Automatic Protect
Overview:
The BC-IA Optical Automatic Protect System (abbr. OAPS) detects the optical power of main equipment or channel by real time to protect optical communication. When the power is under the threshold value which is set by user, the OAPS will switch to standby channel and give warning with current power. If the OAPS detects that the main channel’s power rose over the threshold value, it will switch to main channel and ensure continuous communications.
Product Features: Rapidly respond, give warning and LCD displayLow insertion lossReal time power detecting, plug and playRecover swiftly Applications:The optical channel’s protection and recovery of optical communication netDetect multi-channel in optical transmission system Specifications:Parameters | Specifications |
Operation Wavelength (nm) | 1310±50 or 1550±50 |
Insertion Loss (dB) | ≤1.5 |
Return Loss (dB) | >45 |
Switch Time (ms) | <20 |
Adapter | FC/PC * |
Optical Power Range (dBm) | -50~+20 * |
Measurement Precision (dB) | ±0.5 |
Warning (threshold) Value (dBm) | 20 (default, can adjust by user) |
Power Supply (V) | DC 48 or AC 220 |
Power Consuming (W) | <2 |
Dimension | standard 1U (19 inch) * |
Operation Temperature (°C) | 0~60 |
Storage Temperature (°C) | -20~70 |
Luminous power supervision module |
Optical Automatic Protect system