Operation: auto move battery into machine,sensed by electric eye and located accurately,test mould go down to the position,electric up and down rolling path lower to the tank, machine begin blow to the inner side of the battery,if unqualified,alarm will sound and give out light, unqualified one will be pushed out of water and move to the other branch.if qualified,battery will be moved to the next work section
Testing speed:80 per hour
Testing accuracy: 100Kap pressure point,0.1%. 20Kpa pressure point,0.5%
Testing pressure: 0-100Kpa
Testing time:0-99s, adjustable
Power: AC380V,50HZ, 2KW
Gas power: 0.1m3/min,0.6Mpa
Volume(L*W*H):2000×1690×2450mm
Weight:1000Kg
XQM-900TMS Automatic water bath small cap gas tightness testing machine