Single Output Switching Power Supply
Single Output S-120 Series Feature: High efficiency, high reliability, lost costUniversal AC input range selected by switch100% full load burn-in testLED indicator for power onProtections: Short circuit/Over loadCooling by free air conventionFixed switching frequency at 25 KHz1 year warranty | |||||||||
Model | S-120-5 | S-120-12 | S-120-15 | S-120-24 | |||||
Output | DC Voltage | 5V | 12V | 15V | 24V | ||||
Voltage Tolerance | ±2% | ±1% | ±1% | ±1% | |||||
Rated Current | 24A | 10A | 8A | 5A | |||||
Current Range | 0-24A | 0-10A | 0-8A | 0-5A | |||||
Rated Power | 120W | 120W | 120W | 120W | |||||
Ripple & Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |||||
DC Adjustment Range | -5%,+10% | ±10% | ±10% | ±10% | |||||
Setup, Rise, Hold Time | 200ms,50ms,30ms at full load | ||||||||
Input | Voltage Range | 85-132VAC/170-264VAC 47-63Hz; Selected by switch 255-370VDC | |||||||
AC Current | 2.4A/115V 1.2A/230V | ||||||||
Efficiency | 78% | 81% | 81% | 84% | |||||
Inrush Current | Cold start 20A/115VAC 40A/230VAC | ||||||||
Leakage Current | less than 1mA/240VAC | ||||||||
Protection | Over Load | 105%-150% | |||||||
Protection type: Fold back current limiting, recovers automatically after fault condition is removed | |||||||||
Environment | Working Temp., Humidity | -10 °C- +60 °C; 20%-90% RH | |||||||
Storage Temp., Humidity | -20 °C- +85 °C;10%-95 %RH | ||||||||
Vibration | 10-500Hz,2G 10min./1cycle, period for 60 min, each along X, Y, Z axes | ||||||||
Safety | Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | ||||||||
Standard | Safety Standard | Design refer to UL1012,UL60950,UL1950 | |||||||
EMC Standard | Design refer to FFC Part15 J Conduction Class B,En55022 | ||||||||
Others | Weight | 0.62Kg | |||||||
Dimensions | 199*98*38mm(L*W*H) |