               Model

Specification

  MS-15-5

  MS-15-12

  MS-15-24

DC output voltage

    5V

    12V

  24V

Output voltage rang(Note:2)

  +/-2%

  +/-1%

 +/-1%

Rated output current

   3A

   1.3A

  0.7A

Output current range

  0-3A

  0-1.3A

  0-0.7A

Wave and noise(Note:3)

  500mVp-p

  500mVp-p

  500mVp-p

Inlet stability(Note:4)

  +/-0.5%

  +/-0.5%

  +/-0.5%

Load stability(Note:5)

  +/-1%

  +/-0.5%

  +/-0.5%

DC output power

  15W

  15.6W

  16.8W

Efficiency

  65%

  68%

  72%

Adjustable range for DC voltage

+10,-5%

+/-10%

  +/-10%

AC input voltage range

AC100~240VAC  47~63Hz;

240~370VDC

Input current

0.5A/115V   0.25A/230V

AC inrush current

Clod-start current 15A/115V 30A/230V

Leakage current

   <0.5 mA/240VAC

Overload proctection

105%~135%Type:pulsing hiccup shutdown Reset:autorecovery

Over-voltage proctection 

105%~135%Type:pulsing hiccup shutdown Reset:autorecovery

High-temperature  and protection

105%~135%Type:pulsing hiccup shutdown Reset:autorecovery

Temperature coefficient

  +/-0.02(0~50)

Setup, rise,hold up time

200ms,100ms,30ms

Vibration

10-500Hz,,2G10min,/cycle, periodfor 60min,Each axes

Withstand voltage

Input and output interal:1.5KvAC,Input ad enclosure:1.5KvAC

Output and enclosure:0.5KvAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ

Working temperature and humidity

-10+60(Refer to output derating curve),20%90%RH

Stoerall dimension

-20+85.10%~95%RH

Overall dimension

120*46*32mm

Weight

0.3Kgs

Safety standards

Meet UL1012 requirement(Not apply for the mark)

EMC standaras

Meet FCC PART15J Conduction class B

Note:1The testing condition for the paramenter aboveis:230VAC input,rated load,2570%RH

Temperature.

2Error.include the setting error,line stability and load stability.(Note;5).

3Wavetest:adoptingA12 double wire for 20MHz,and0.1UF and 47UF  capacitor short-circuit fou interrupting

4Inlet voltage stability test: when is over load,the lowest voltage of inlet is up to the highest voltage.

5Load stability test:The load is from 0%to 100%