WZ series Industrial assembly type thermal resistance
1. Application
It is usually connected with display meter, recording meter and computer ect. To directly measure the temperature of liquid, vaper, gas and solid surface ranging from -200 to 600°C during various production processes.
2. Features
Simple structure and good stability performance.
High measuring accuracy.
High mechanical strength, good pressure-resisting performance.
3. Working principle
It is based on that when temperature of object changes, the resistance will change accordingly, to measure temperature when the resistance value changes, the working meter will display relevant temperature.
4. Main technical parameters
Standard
IEC751
JB/T 8622-1997
JB/T 8623-1997
Temperature measuring range and Tolerances
Calibration | Nominal resistance(0°C) Ω | Temperature measuring range °C | tolerance | R100/ Ro w |
Pt10 | 10 | ceramic elements:-200 ~ 600 mica elements: -200 ~ 420 | ClassA: ±(0.15+0.2%|t|) ClassB: ±(0.3+0.2%|t|) | 1.3851 |
Pt100 | 100 | |||
Cu50 | 50 | -50 ~ 100 | ±(0.3+0.6%|t|) | 1.4280 |
Cu100 | 100 |
Note: The Tolerances of other calibration may consult the above RTD tolerances scope.
thermal response time
Diameter of protective(mm) | Material of protective | Thermal response time(s) | |
Platinum resistance | ¢12 | Carbon steel:20 Stainless steel:0Cr18Ni12Mo2Ti;1Cr18Ni9Ti | 30~90 |
¢16 | |||
Taper protective tube | Stainless steel :1Cr18Ni9Ti | 90~180 | |
Copper resistance | ¢16 | Brass:H62 Carbon steel:20 Stainless steel:1Cr18Ni9Ti | ‹180 |
Diameter of protective tube(mm) | Length L |
¢12 | 225,250,350,400,450,550,650,900,1150 |
¢16 | 300,350,450,500,650,900,1150,1650,2150 |
Taper protective tube | 225,250,300,400 |