electrical resistance thermocouple
1.Measurement chart
D-1 | L | D-2 | D-3 |
1.0 | 36 | 6.5 | 5.5 |
1.6 | 36 | 6.5 | 5.5 |
2.3 | 36 | 8.0 | 7.0 |
3.2 | 36 | 8.0 | 7.0 |
4.8 | 43 | 10.0 | 7.0 |
6.4 | 43 | 10.0 | 8.0 |
8.0 | 50 | 12.0 | 8.0 |
2.Code of graduation
Category | Ni-Cr-Si--Ni-Si-Mg | Ni-Cr--Ni-Si | Ni-Cr--Cu-Ni | Fe--Cu-Ni | Cu--Cu-Ni |
Code of graduation | N | K | E | J | T |
Types of measuring junctions | Insulated /Shelled junction type | Insulated /Shelled junction type | Insulated /Shelled junction type | Insulated /Shelled junction type | Insulated /Shelled junction type |
3. Speed reaction chart
Speed reaction(per second) pipe diameter(mm) | Grounded type | Non-grounded type | ||
Room temperature-100°C | 0°C-750°C | Room temperature-100°C | 0°C-750°C | |
1.0 | 0.13 | 18.0 | 0.16 | 20.5 |
1.6 | 0.26 | 33 | 0.36 | 38 |
2.3 | 1.0 | 68 | 1.1 | 88 |
3.2 | 1.3 | 86 | 1.9 | 104 |
4.8 | 2.7 | 147 | 4.1 | 174 |
6.4 | 4.0 | 215 | 6.8 | 254 |
8.0 | 260 | 330 |
4.
Advantage
Easy to bend
Bear high voltage
Quick temperature reaction
Reliability ,stability and durability
5.
Plastic injection molding machinery
Food processing equipment
Engine and turbine exhaust gas
Semiconductor processing
Heat treating and metals processing