Product Characteristics:
1.High temperature resistance up to +150C, and suitable for brief exposure to temperature up to +175C.
2.Optimize the thermal efficiency of whole pipeline system , and save time during installation.
3.Weather and UV resistant , protected against water vapor diffusion, increase lifespan of the pipeline.
4.The protection film avoids the animal harms like the birds pecking and rats gnawing .
Aeroflex Insulation Technical Data Sheet:
PHYSICAL PROPERTIES* | TEST METHOD | |||||||||
Cell structure | AEROFLEX closed cell | |||||||||
Density lb/ft.3 (g/cm3) | 3-65 (0.048-0.096) | ASTM D 1667 | ||||||||
Thermal conductivity | mean temp. | -4°F(-20°C) | 32°F(0°C) | 75°F(24°C) | 90°F(32C°) | 104°F(40°C) | ASTM C 177 JIS A 1412 DIN 52613 | |||
K.Value | 0.22(0.032) | 0.23 (0.034) | 0.25 (0.037) | 0.26(0.038) | 0.27 (0.039) | |||||
Service temperature | (-57°C to +150°C),shortly for +175C | AEROFLEX starts to become harder -57°C but and can be used even at -200°C | ||||||||
Water vapor permeability (perm-in) | 0.10 perm-in (0.15 x 10-12) | ASTM C 355, E 96 | ||||||||
>5,000 | DIN 52615 | |||||||||
Water absorption (% by weight) | 5 | ASTM D 1056 | ||||||||
ozone resistance | Excellent | ASTM D 1171 | ||||||||
Thermal stability | 7 days 200°F | 6 | ASTM C 534 | |||||||
(% shrinkage) | 7 days 200°F | 6 | ||||||||
Flammability & Smoke Developed | Class VO | UL-94 | ||||||||
25/50 | ASTM E84 | |||||||||
Self extinguishing | ASTM D 635 | |||||||||
Class 5.3 | EMPA (Switzerland) | |||||||||
U.V. weather resistance | Excellent | |||||||||
Corrosion of copper, stainless | Noncorrosive | DIN 1988 | ||||||||
Nitrosamines content | Not detected | US.FDA | ||||||||
Sound reduction | 27 Db (20mm) | -DIN 52218 |
1.Specifications comply with ASTM C534-88.
2.Figures show the average values obtained by the world well-known testing institutes.
3.Tested according to DIN, JIS, ASTM and others.
3.Average density of insulation thickness over 20 mm.
5.At temperature. under -57 °C AEROFLEX becomes hard, but it does not affect thermal conductivity nor water vapor permeability. In the heating applications AEROFLEX can stand +150 °C continuously, and short term to +175 °C.
6.Water vapor permeability tests were done under test method ASTM E96 dehydrate test method at 37.8 °C.
7.It is reported that Nitrosamines is harmful to human health even during storage. No Nitrosamines compound was detected in AEROFLEX.
1.AEROFLEX flexible closed cell insulation is most effective in reducing heat loss form indoor and outdoor hot water piping systems in hospitals, hotels, residential buildings and industrial plants.
2.AEROFLEX also proves to be the most suitable insulation for outdoor pipe line of Solar Energy Heating System.
3.Aeroflex is manufactured from synthetic polymers which contain no asbestos or fibrous material . This is one of installed in places where hygiene is vital. the many reasons why AEROFLEX is widely selected as a replacement for fibrous material like fiberglass or rock wool used in hot water piping of up to 100 °C in hotels, hospitals and industrial or residential applications. The closed cell structure and specially-selected elastomeric materials offer.
4.A stable K value and outstanding weather resistance is offered throughout service life. AEROFLEX is widely used for indoor and outdoor heating & cooling systems, replacing fiberglass and calcium silicate.
5.Two years exposed to sunlight experiments proves that AEROFLEX has outstanding ultraviolet and weather resistance. The service life under normal conditions for hot water pipes is estimated at more than 10 years.
Big Size EPDM Foam Insulation Tube with UV Resistant Film for Thermal Heating Systems