1. Contact Form: 2Z
2. Contact voltage and load current :12-24VDC Max 200A
3. Contact resistance: 30mΩMax, 20 ± 5 °C low temperature, the maximum motor voltage (VDC) exposure to no more than 70% of rated voltage, rated voltage tripping of 5% to 30%
4. Mechanical Life (Min.): 100,000 Ops
5. Electrical Life (Min.): 50,000 Ops
Coil parameters
1. Coil rated voltage :12-24VDC
2. Coil rated voltage, maximum current: 0.8A
3.20 ± 5 °C maximum starting current when the power circle: 2.5A
Performance parameters
1. Insulation resistance: 100MΩMin
2. Between coil and contacts: Between Contacts 2000VAC, Between coil and contacts 1500VAC
3. Ambient temperature and altitude: -40 °C ~ +85 °C; 0 ~ 20000m
4. Maximum relative humidity: 98%
5. The impact of the fixed points: the frequency (11Z) 10 ~ 200, the speed (g) ≤ 3.5
6. Impact: speed (time / min.) 60 ~ 100, the speed (g) 4
7. Continued acceleration: 8
8. Operating rules (continued): Continuous
9. Mounting direction (random): any