Quick Details
Place of Origin : Zhejiang, China (Mainland) Brand Name : Huilong Cang Model Number :973
Theory : Electromagnetic Relay Usage : General Purpose Size : Subminiature
Protect Feature : Sealed Contact Load : High Power
Environmental friendly product (RoHS compliant)
Order information
973——12VDC——SL——A 1 2 3 4 1 Model:973 2 Coil Voltage(V):3,5,6,9,12,18,24,36,48 3 Package Type: SL: Sealed No: Dust-proof 4 The Contact Form:A:1A;B:1B;C:1C |
Applications
Household Appliances, Car automation system, Electronic equipment , Communication devices , etc
Contact Data
Contact Form | 1A(1H) (SPSTNO) ,1B(1D) , 1C(1Z) (SPDT(B-M)) | |
Contact Material | AgCdO AgSnO2 | |
Contact Load | 5A 240VAC, 7A 240VAC/24DC, 10A 250VAC/240VAC/125VAC/24VDC, 15A 24VDC, 20A/125VAC/14VDC | |
Max Switching Power | 336W 2500VA | |
Max Switching Voltage | 110VDC 380VAC | |
Max Switching Current | 20A | |
Contact resistance | ≤100mΩ | |
Life | Electrical | 10 5 |
Mechanical | 10 7 |
Coil Data
NO. | Coil Voltage VDC | Coil Resistance Ω±10% | Suction Close Voltage VDC (Max) (Rated voltage of 75%) | Release voltage VDC (Min) (Rated voltage of 10%) | Coil Power W | |
Rated | Max | |||||
1 | 3 | 3.9 | 25 | 2.25 | 0.3 |
0.36 |
2 | 5 | 6.5 | 69 | 3.75 | 0.5 | |
3 | 6 | 7.8 | 100 | 4.50 | 0.6 | |
4 | 9 | 11.7 | 225 | 6.75 | 0.9 | |
5 | 12 | 15.6 | 400 | 9.0 | 1.2 | |
6 | 24 | 31.2 | 1600 | 18.0 | 2.4 | |
7 | 36 | 46.8 | 3600 | 27.0 | 3.6 | |
8 | 48 | 62.4 | 6400 | 36.0 | 4.8 |
NO. | Coil Voltage VDC | Coil Resistance Ω±10% | Suction Close Voltage VDC (Max) (Rated voltage of 75%) | Release voltage VDC (Min) (Rated voltage of 10%) | Coil Power W | |
Rated | Max | |||||
1 | 3 | 3.9 | 20 | 2.25 | 0.3 |
0.45 |
2 | 5 | 6.5 | 56 | 3.75 | 0.5 | |
3 | 6 | 7.8 | 80 | 4.50 | 0.6 | |
4 | 9 | 11.7 | 180 | 6.75 | 0.9 | |
5 | 12 | 15.6 | 320 | 9.0 | 1.2 | |
6 | 24 | 31.2 | 1280 | 18.0 | 2.4 | |
7 | 36 | 46.8 | 2880 | 27.0 | 3.6 | |
8 | 48 | 62.4 | 5120 | 36.0 | 4.8 |
NO. | Coil Voltage VDC | Coil Resistance Ω±10% | Pull-in Voltage VDC (Max) (Rated voltage of 75%) | Release voltage VDC (Min) (Rated voltage of 10%) | Coil Power W | |
Rated | Max | |||||
1 | 6 | 7.8 | 45 | 3.4 | 0.9 | 0.8 |
2 | 9 | 11.7 | 100 | 5.2 | 1.35 | |
3 | 12 | 15.6 | 180 | 6.90 | 1.8 | |
4 | 24 | 31.2 | 720 | 13.8 | 3.6 |
Note: 1.If the coil voltage is lower than the rated will damage the relay work.
2.Suction close voltage, release voltage is only for inspection, not the use index of design
Security Certification
Security Certification | CQC | UL | TUV |
Load | 10A/250VAC | 5A/240VAC 10A/240VAC 10A/24VDC 15A/24VDC | 1A/24VDC 7A/240VAC 10A/125VAC |
Packaging materials
Product model | Package number | Carton size (CM) | Number (PCS/Carton) | Net weight (kg) | Gross weight(kg) |
973 series | 100PCS | 38.5*30*18 | 2000 | According to the real | According to the real |
Welcome HLC