Drop out fuse cut out and and load switching fuse cutout are of outdoor used high voltage protective device. Drop out fuse cut out and and load switching fuse ... and on/off loading current. Cut out fuse is composed of insulate insulators and fuse tube, static contacts is fixed on ... on two ends of fuse tube. Fuse tube is composed of inside arc-extinguishing tube, out phenolic compound paper tube ...
... outdoor h.v.Current-limiting fuse is used for protecting for voltage transformer,protecting from overload,fuse RW10-35 type outdoor h ... .v.Current-limiting fuse is used for protecting for voltage ... of rated current,it melts in 1 hour.(high voltage fuse,cut out fuse,fuse)
Fuse Holder 1.high-temperature resistance plastics, 2.not fragile plastics. Negative pole 1 in to 5 out fuse holder Order quantity100~200pcs200~500pcs≥500pcsPrice282725Update Date:2011-11-07 22:47:23 Negative pole 1 in to 5 out fuse holder
Polymer fuse cutout, rated voltage from 10kv to 36kv, current 100A, 200A We can supply polymer fuse cutout, rated voltage from 10kv to 36kv, current 100A or 200A. Polymer fuse cutout
... level of aging resistance. 4. Leakage distance:790mm Fuse Cutout with Polymer Base is an outdoor protection product for power system ... also conforms to IEC282-2 standard.Detailed Specifications of the Fuse Cutout: Rated Voltage, kV3636Rated Current, A100200Rated Breaking Current, ... kV9595Leakage Distance, mm790790Height, mm600600Tube Length, mm480480Weight, kg5.65.8 Fuse Cutout with Polymer Base
... 2) 415V AC, 60A, 80A, 100A HRC Cutout fuse box and fuse holder1.DescriptionHRC cutouts are made of high grade phenolic moulding ... of use.2 .specification1) Cutout to use with BS88 cylindrical fuse links2) Rated voltage: 415V AC3) Current rating: 60A 80A, 100A4 ... ) Complies with the IEC60269 Standards5) with barrier protector shieid Cut-out Fuse Box (all insulated house service cut ...
Competitive price, good quality, best service, Relia is your correct choice! STANDARD: ASME, METRICTYPE: DROP OUT ANCHORGRADE: 2(4.8), 5(10.9), 8(12.9)MATERIAL: CARBON STEEL, STAINLESS STEEL, BRASS, ALUMINIUMSURFACE: PLAIN, BLACK, ZINC PLATED
Standard: BS1361 Single phase ( SP) or SPN cut out fuse Black bakelite/Grey resin materials Al or copper conductor + STANDARD ... /Copper conductors upto 35 sq. mm5. Loop in and Loop out cabling contacts available.RATINGS15 Amps. To 100 Amps. In single ... SRH FUSES conform to BS:1361-1986 House Service cut out ( fuse)
1.certification:ISO9001 2.material:brass 3.produce according to the client's requirements 4.OEM orders are welcome Cutout fuse brass casting partsmaterial: brassfinish: sanding polish, Tin plating, silver platingproduce as your special needs
reliable quality ,competive price,fast delivery ,good sevice. The technical specification: 1. The density≥1.80g/cm3 2. Water absorption rate≤0.15% 3. Bending strength≥400Mpa 4. Compression strength≥98Mpa 5. Withstand voltage along laminas at normal condition 5 min ≥25KV 6. Withstand voltage across laminas at transformer oil 90±2oC 5min ≥12MV/m Note: The diameter according to customer's order.
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.