... 1. The product is applicable to the outlet of the current transformer of transformer with the voltage over 110kv and power station, 2 ... is also applicable to the iron core ground connection of transformer instead of the earthing sleeve.Main Feature1.Using vacuum die ... conduction rod radically solves the issue of oil leakage of transformer from copper conduction rod. 3.For the purpose of perfect ...
... front-end maintenance, the switchgear is equipped with a special current transformer, so that the operator can maintain and inspect it in ... withstand voltagekV7595/1258Rated short circuit breaking current (peak)kA40/50/63/80/1009Short time withstand current(4s)kA20/25/31.5/4010Protection ...
... are made up of LF-0.5B anti-power-stealing current transformer group,low vacuum load switch, IC card type prepaid watt ... the commom indoor Low Voltage prepaid measuring tank ,they reduce 60%of the cost,and are more propitious to be popularized ...
... fire and the detonation hidden danger;e The internal installation current transformer measuring accuracy reaches 0.2 level, may realize the ... .3~ ~180S~The rating short-circuits the drop-out current to open breaks the number of timestime20The rating short-circuits ... the pass to gather the electric current (peak value)kA50 , 63 , 80Fixed peak value withstanding ...
... There are two ways of connection:direct connection or through current transformer connection.Each performance index of it conforms to GB/ ... . May select anti-tampering function. Main Technical Data Rated Current(A) 3*1.5(6),3*5(20),3*10 ... (40),3*15(60),3*20(80),3*30(100)Rated Voltage(V) ... or 3*57.7/100VRated frequency(Hz) 50 or 60 Accuracy Class Class 1 or Class 2 DTSY3333 three phase ...
... .5A...60A.For 10A-10KA,use external current transformer.. RectangRound Moving Iron AC Ammeters 1. ... SFT-670, SFT-60, SFT-560, SFT-50.Measuring the alternative current with frequency ranging from ... 10KA,use external current transformer with secondary current 5A or 1A,When Connected directly with current 50A, 60A ... Changeable scale: Under the same secondary current and the identical scale class range, ...
... . Measuring range: 0-600V AC; For the current over 600V can use the AC current transformer 6. Consumption: <3.2VA 7. Max. Signal ... ~50 C degree humidity: ≤85% 9. Storage environment: Temperature: -30~60 C degree, humidity: ≤70% 10. Heat resistance: Case of non ...
... 48lightning withstands voltage(peak)pole to pole, pole to groundkv40, 60, 75fracture to fracturekv46, 70, 85Protection degreeEnclosure is IP4X. IP2X ... CB door are openNote:1. The short-circuit capacity of current transformer is considered separately. 2. Details of the parameters of ... wall so as to save space.8) Installation of current transformer:a. Frontal-mounted in the cable compartment which is ...
... continuous working is allowed at maximum power output.Constant current or constant power status can be selected accordingly to ... higher heating efficiency;Display of heating power and heating current and oscillating frequency.Simple to install , installation can ... Input voltage scope340V~420V Output osc. Frequency30~80KHZ Heating current 10A-52A10A-70A10A-100ADuty cycle100% Requirement for cooling ...
... by MSVT (multi secondary voltage transformer) output, which suits for the voltage/current close-link test of signal phase ... 0. 05 /0. 1Standard CT (current transformer) class: 0. 01/0. 02MSVT (multi secondary voltage transformer) class: 0. 02Primary voltage: 180- ... 15VA per windingInsulation secondary to secondary: 500V, 50Hz, and 60 secondsPrimary to secondary ratio accuracy: +-0. 1% (typical) ...
... perform data logging for various parameters such as voltage, current, power, harmonics, demand and energy into a Microsoft ... panel, users can modify settings such as potential and current transformer ratios, wiring diagram selections, alarm parameters, network settings ... from 1-60 min (1 min increments) can be set according to different applications• Individual voltage and current harmonic recordings ...
... (MMA),10-200A(TIG),15-50A(CUT)RATED DUTY CYCLE: 60%CURRENT UP-SLOPE TIME: 0-10SGAS POST FLOW TIME:1-25SCURRENT ... FOR MMA2T/4T AND PULSE CONTROL FOR TIGDIGITAL DISPLAY AND CURRENT PRESET ADJUSTMENTSUITABLE FOR FOOT PEDAL TO ADJUST THE TIG WELDING ... CURRENTOVER HEATING AND CURRENT PROTECTIONSTANDARD ACCESSORIES:1PC WP26 TIG TORCH WITH 4M CABLE1PC 300A ...
... electrod welding machines for professional welding in alternating current (AC). Stepless regulation of welding current.Usable electrodes: rutile. Technical specification MODELBX1-140EBX1 ...
... reliable. Each VCB canequip with 6-12pieces of current transformer according to customer’s requirement.The design performance strictly ... our national standard GB1984 - 89 for high voltagealternating current vacuum circuit breaker, and meet the requirements of International ... Commission (IEC) IEC-56 for high voltage alternating current vacuum circuit breaker. Ithas characteristics of simple structure, ...