... equipments used eletricity such as high-voltage motor of 12kV or under 12kV, transformer and capacitive loading etc. Especially suitable for frequent ... ).Rated Parameters: Main Technical Parameters: JCZ5-12J(D).Rated Voltage: 12kV.Rated current: 800A, 630A, 400A, 200ARated turn-on current: ... Withstand Voltage: 42kVLightning impulse withstand voltage: 75kVSize: 510mm*240mm*450mm 12kV Vacuum Contactor
switchgear 1:induced ABB's technic,,high flame retardant materail was ... 2:compact desing,save space MNS low voltage draw-out switchgear(indoor)Main technicial Parameters Rated isolation voltage660VRated frequency50HzRated voltage of ... GB7251.1-2005 IEC 439standard low voltage draw out style switchgear
End Fitting For Switchgear 1.mechanical class:40kn-210kn 2.IECstandard Application:mainly for insulators used in power transmission and distribution linesRated Strength:40KN-210KNProperties:hot dip galvanied coating protection against corrosion End Fitting For Switchgear
... substations even under severe environmental conditions Power Distribution switchgear Cabinet is used for power distribution in substations ... dusty areas3. Simple outdoor substationsTechnical features1. Secondary distribution switchgear designwith up to 5 feeders2. Maintenance-free3. Climate- ... -enclosed6. Insulating gas SF67. Gas-tight, welded switchgear vessel made of stainless steel, with welded-in ...
1.FN5-12 load break switch 2.Indoor install pole mounted 3.IEC420 GB3804 4.OEM and XIKAI 5.12kV 630A 50Hz Power Systems FN5-12 load break switch is indoor high voltage products.This swich is installed indoor.We provide OEM for customers.2013-01-05 FN5-12 12kV Load Break Switch, Air Break Switch (IEC420)
... The functional units completely separated or partially separated3.3 Switchgear dimensions a Height (mm): 2200 b Width (mm ... S, TN-C-STechnical Parameters: 1. For the switchgear of IP54,the min. depth is 728mm 2 .For ... . If the depths are not unified a busbarexchange switchgear with depth of 400mm should be added 3 ... .The depth of the switchgear should be≥800mm , If there is Incoming and ...
This switchgear is applicable for distribution, motor, centralized control, reactive power compensation ... voltage, reduce short cicuit intensity requirement. GCS Indoor Withdrawable LV Switchgear
... current, over-load current and short-circuit current in outdoor 12kV three-phase alternating current 50Hz power system, also suitable for ... time withstand current/durationkA/s20/48Mechanical lifeTime100009Net weightkg60 ZW43A-10 12kV High Voltage Outdoor Pole Mounted three phase Vacuum Circuit Breaker ...
ZW6-12 Series outdoor HV vacuum breakers, 3P,50hz,12KV, can be with fuse protection. ZW6-12 Series outdoor HV vacuum breakers, 3P,50hz,12KV, can be with fuse protection.
3~12kv Post Type Series Current Transformer, Full Operational mode with protective class, Casting Type, Increased-capacitance 3~12kv Post Type Current Transformer