Table 1 Electrical Measurement Ranges
Parameter | Range | Resolution | Notes |
Voltage | 0* - 60 V | 0.01 V | *0 V min. w/ auxiliary power. E.g. a receiver battery. Else 4.0V. |
Current | 0 -100 A peak | 0.01 A | 50 A continuous |
Power | 0 - 6554 W | 0.1 W | |
Charge | 0 - 65 Ah | 0.001 Ah | 0-6554 Ah for Doc Wattson. 0.1Ah resolution |
Energy | 0 - 6554 Wh | 0.1 Wh | 0 -655 Kwh for Doc Wattson. 0.01KWh resolution |
Table 2 Miscellaneous Specifications
Parameter | Value | Notes |
Measurement Update Period | 400 mS | 650 mS for Doc Wattson |
Signal Sampling Rate | ???? samples/s | |
Data Queue Sequence time | 2 seconds | |
In Circuit Resistance | 0.001 Ohms | |
Operation Current | 7 mA | |
Auxiliary Power Voltage | 4.0 V - 60 V | e.g. from a receiver battery |
Dimensions | 2.8" L x 1.7" W x 0.83" D | |
Weight | 2.3 oz. | 1.7 oz. without case |
Display Screen | 16 character x 2 row STN LCD | |
Nominal Operating Conditions | 0°- 50 ambient temperature, non condensing humidity | Maximum temperature must be reduced at maximum current rating |