Name: LIFT-2S Lift & Hoist Control Cable, 300/500V
Application
These cables are used as control or feeder cables in lifts and hoists. Ideally installed onto the pendant manual control unit.
The two steel wire reinforcement act as stress or torsion protection to cable of the control unit of the system.
Construction
Conductor | Finely stranded copper conductor IEC 60228 cl.5 |
Insulation | PVC insulation textile banding |
Lateral suspension wire | Sheathed stranded steel wires |
Cores identification | White cores with black printed numbering, green-yellow earth core in the outer layer |
Outer sheath | PVC, Black colour Ozone resistance, oil resistance, moisture resistance, chemical resistance, U.V resistance, weather resistance & flame retardant (IEC 60332-1) |
Technical Data | |
Nominal voltage | 300/500 V |
Test voltage | 3000v |
Temperature range. | Flexing:-5°C to +40°C fixed: -40°C to +70°C |
Max conductor Temperature range. | Under load: +70°C Circuit conditions: +150°C |
Min. bending radius | approx: 20 x cableφ |
Specifications:
No of cores X cross-sec. | Approx.outer diameter | Approx. cable weight | Support core | Pendant length cable(m) |
12 x 1.0 | 15.0 | 446 | steel | 0 |
18 x 1.0 | 17 | 528 | steel | 0 |
25 x 1.0 | 21.2 | 660 | steel | 0 |
30 x 1.0 | 22 | 760 | steel | 0 |
8 x 1.5 | 15.0 | 425 | steel | 0 |
12 x 1.5 | 16.4 | 505 | steel | 0 |
15 x 1.5 | 18.6 | 575 | steel | 0 |
18 x 1.5 | 19.2 | 640 | steel | 0 |
20 x 1.5 | 21.0 | 715 | steel | 0 |
24 x 1.5 | 22.6 | 820 | steel | 0 |
LIFT-2S Lift & Hoist Control Cable, 300/500V