Thermocouple extension wire
1.Conductors:Positive Chromel
Negative Alumel
2.Insulation:Extruded PFA
3.Overall Jacket:PFA
1, SUBJECTThis specification covers the requirements for PFA insulated thermocouple extension cable, type KX,solid wire, 2x36 AWG, standard tolerances and color coding according to ASTM E 230/ANSI.2, TECHNICAL FEATURESA. Conductors:Solid thermocouple extension wire
Conductor Size (AWG) |
36AWG(Ø0,127mm) |
B. Insulation:Extruded PFA (260ºC)Nominal Insulation Thickness: 0.10mmColor code - ANSI/ASTM E230
Positive | Color |
Chromel | Yellow |
C. Assembly: Two conductors (positive and negative) parallel construction.D. Overall Jacket:Extruded PFA (260ºC)Nominal Insulation Thickness: 0.10mm
Color code: | Yellow or White/yellow trace |
(ANSI/ASTM E230)3, DIMENSIONS AND TOLERANCES
Dimensions / tolerances (mm) |
0.5±0.15 X 0.8±0.15 |
4, CALIBRATION TOLERANCE
Temperature range | Standard tolerance* | Special tolerance* |
0°C to 200°C | ±2,2°C or 0.75% | ±1,1°Cor 0,4% |
Thermocouple type available: KX, JX, TX, EX, NX, RX,SX and other compensating cable like KCA, KCB and so onColor Code available:
Type KX- 2x36AWG PFA/PFA - ANSI Thermocouple Extension wire