Thermocouple Cable (Heat Resistant):
The implement standard of our compensating cable is GB/T4989-94(type SR thermocouple),JB/T9496-99(WRe3/25WRe5/26 thermocouple)
Thermoelectricity characteristic of the compensating cable:
Compensating Cable type | Thermocouple calibration matched | 100emf standard value (uv) | 200emf standard value (uv) | Tolerance | Material | ||
Precision | Normal | Positive pole | Negative pole | ||||
SCRC | SR | 645 | 1440 | ±10uv | ±60uv | Cu | Cu-Ni |
WC3/25 | WRe3/25 | 1145 | 2602 | ±20uv | ±48uv | Cu | Cu-Ni |
BC | B | Cu | Cu | ||||
WC5/26 | WRe5/26 | 1451 | 3089 | ±51uv | Cu | Cu-Ni |
Specification of the compensating cable:
The dimension of the compensating wire is 0.4*1.0mm,this compensating wire is used for made the expendable thermocouple; normal compensating cable used for connecting the indicator,the cross section area is 1.0 mm2,the outer diameter is 5.1*8.0mm;the heat resistant compensating cable used inside the lance,the cross section area is 1.0 mm2,the outer diameter is 3.1*5.6mm.