Product Detail
Electric Floor Heating Cable 220V 1.Rated voltage: 220V 50Hz 2.Pressure:300/500V 3.Linear powe:18W/M,

Electric Floor  Heating Cable 220V

Electrical Performance

Reference Standard:

1.JGJ 142—2004 Technical specification for floor radiant heating

2.IEC 60800:1992 Rated voltage 300/500V heating cable for life

facility heating and guards against

 Test Item                                                                     Unit         Spec

1.Product temperature cable voltages          2.0 kV/5min    No breakdown

2.Product temperature cable voltages (100 °C)   1.5 kV/15min    No breakdown

3.Min.Subsequent insulation resistance (100°C)       MΩ·km       0.03

4.Standard resistor errors (20°C)                         Ω/m        -5% ~ +10%

5.Temperature coefficient of resistance                              Should be a

                                                                                                       positive number

6.Maximum grounding resistance (20°C)         Ω/m          ≤0.0181

7.Continuity of conductors, shielded                    —          Continuous

Product structure

Heating Conductor

Shield

Material

Copper-nickel alloy

Outside insulation

Form

Patch

Polyester belt form

Longitudinal layer of polyester

Number

7 Root

Polyester material

PET

Diameter

Φ 0.30±0.02 mm

Polyester belt specifications

0.25×12 mm

Cable Core

1 Core

Braid material

TC - Tinned Copper

Insulation

Braid

16×3×TCΦ0.10 mm

Material

Silicone rubber

Covered

≥ 35%

Thickness

1.00±0.05 mm

Braid outside

Diameter

Φ 3.00±0.10 mm

Polyester belt form

Longitudinal layer of polyester

Number and color

1 Root:Transparent Color

Polyester material

PET

Marking

Per Customer Request

Polyester belt specifications

0.25×14 mm

Outer Jacket

Material

PVC - Polyvinyl Chloride

Thickness

1.35±0.05mm

Color

Blue & Red

Diameter

6.50 +/- 0.30 mm

Single heating cable specifications ( 220V 18W/M)

  Product Type

Rated power(W/ROOT)

Standard length(M/ROOT)

Nominal resistance(Ω/ROOT)

RXRL/1R300/18

300

16.67

161.33

RXRL/1R500/18

500

27.78

96.8

RXRL/1R800/18

800

44.44

60.5

RXRL/1R1000/18

1000

55.56

48.4

RXRL/1R1500/18

1500

83.33

32.27

RXRL/1R1800/18

1800

100

26.89

RXRL/1R2300/18

2300

127.78

21.04

RXRL/1R2500/18

2500

138.89

19.36

RXRL/1R3000/18

3000

166.67

16013

Remarks: according to customer requirements