It has the following features:
1) cold-resistance(-40°C0;
2) oil-proof(refrigerant and lubrication oil);
3) distortion resistance;
4) flame retardant;
5) sea water corrosion resistance.
It is produced according to standard TICW/01-2009.
Conductor material: superfine stranded bare copper wire
Conductor structure: the fifth copper or tinning copper conductor specified in GB/T3956-2008
Withstand test of power frequency alternating current:
The rated voltage 450/750v cable: 2.5kv/5min, no breakdown
The rated voltage 0.6/1kv cable: 3.5kv/4h, no breakdown
The rated voltage 1.8/3kv cable: 6.5kv/4h, no breakdown
The continuous maximum conductor temperature for operation of the cable: it is 70°C if the voltage class is 450/750v; while the other two classes are 90°C..
The maximum short circuit(not more than 5s) temperature of the conductor: If the insulation is IE4 type, the temperature is 140°C. If the insulation is EPR or G type, the temperature is 250°C.
The Min. bending radius: it is not less than 6 times of the outer diameter of the cable.
The Min. environment temperature can be -25°C if it is ordinary cable, while the temperature can be -40°C if it is cold-resistance cable, and the temperature can be -55°C if it is severe-cold-resistance cable.
It has strong mechanical properties and high flexibility.
It has property of flame retardance: if it is single core, the test result satisfy standard GB/T18380.11-2008, if it is bundled cables, the result satisfy state standard GB/T18380.31-2008.
The service life time can be longer than 20 years according to the test result.
type | Rated voltage | Name |
FDEF-25(-40) | 450/750V | copper core EPR insulated neoprene sheathed (cold-resistant) distortion resistance flexible cables for wind power plant |
FDES-25(-40) | 450/750V | copper core EPR insulated thermoplastic elastomer sheathed (cold-resistant) distortion resistance flexible cables for wind power plant |
FDGG-40(-55) | 0.6/1kV 1.8/3kV | copper core silicone rubber insulated silicone rubber sheathed cold-resistance (severe-cold-resistant) distortion resistance flexible cables for wind power plant |
FDGU-40(-55) | 0.6/1 kV 1.8/3kV | copper core silicone rubber insulated PU elastomer sheathed cold resistance (severe-cold-resistant) distortion resistance flexible cables for wind power plant |
FDEU-40(-55) | 0.6/1kV 1.8/3kV | copper core EPR insulated PU elastomer sheathed cold resistance (severe-cold-resistant) distortion resistance flexible cables for wind power plant |
FDEG-40(-55) | 0.6/1kV 1.8/3kV | copper core EPR insulated silicone rubber sheathed cold resistance (severe-cold-resistant) distortion resistance flexible cables for wind power plant |
FDEH-25(-40) | 0.6/1 kV 1.8/3kV | copper core EPR insulated CSPE rubber sheathed (cold-resistant) distortion resistance flexible cables for wind power plant |
FDES-25(-40) | 0.6/1kV 1.8/3kV | copper core EPR insulated thermoplastic elastomer sheathed (cold-resistant) distortion resistance flexible cables for wind power plant |
Certification
Our Company and Our Factory
1.8/3kv Distortion-resistance Wind Power Flexible Cable
Verified Information This information is Verified by Bureau Veritas and is valid for the following period: 2012/05/17 --- 2013/05/17 All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >> Production Capacity:Cable and Wire | 490,000km | 437,518km |
Southeast Asia | USD 775,588 | 0.27 |
Africa | USD 54,885 | 0.02 |
Domestic Market | USD 283,335,769 | 99.71 |
Drawing Machine | Shunde Yongxiong, BT22-2 | 14 | 9.0 | Acceptable |
Drawing Machine | Heifei Huaxin, LHD-450/13 | 1 | 12.0 | Acceptable |
Drawing Machine | Shunde yongxiong, ZL250 | 2 | 6.0 | Acceptable |
Frame-Type Strander | Heifei Shenma, JLK-500 6+12+18 | 1 | 3.0 | Acceptable |
1+3 Cable-Former | Shanghai Diangong, JCLL+3/1600 | 1 | 26.0 | Acceptable |
Wire Extruding Machine | Dongguan Jingite, FAI90 | 1 | 3.0 | Acceptable |
Spark Test Machine | Shanghai Lanbo, AWSC-35 60 | 4 | 3.0 | Acceptable |
35KV Cables Cross-Link | Qingdao Woke, 35KV | 1 | 1.0 | Acceptable |
110KV Cables Cross-Link | COLTD, 110KV-CCV-Line)- | 1 | 7.0 | Acceptable |
Metal Shield Machine | Xiangtan Dayangxiangfeng, KRT 630 | 1 | 15.0 | Acceptable |
DC Resistance Measurement Instrument | Shanghai Taiou, PC36C | 1 | 3.0 | Acceptable |
Tension Tester | XLL-500 | 1 | 30.0 | Acceptable |
Electronic balance | Jiangsu Tianrui, EDX1800 | 1 | 2.5 | Acceptable |
Semiconducting Rubber resistance Measurement Instrument | DB-4 | 1 | 10.0 | Acceptable |
Dispersive X-ray Fluorescence Spectrometer | Jiangsu Tianrui, EDX1800 | 1 | 2.5 | Acceptable |
Hygrothermograph | Shanghai Huacheng | 1 | 2.0 | Acceptable |
Shielding lab. For Partial Discharging | Shanghai Lanbo | 1 | 6.0 | Acceptable |
110KV Partial Discharging Test System | HIGHVOLT, SIN305/0315 | 1 | 6.0 | Acceptable |
Certificate of Approval for Fire Resistance | National Supervising Test Centre for Fire Protection of Building Material Quality | Fcz2010079 | Low - Smoke, Halogen-Free Control Cable, WDZAN - KYJY - 450/750V | 2010/06/11 --- 2013/06/10 | |
Certificate of Approval for Fire Resistance | National Supervising Test Centre for Fire Protection of Building Material Quality | Fcz2010078 | Copper Core, XLPE Insulated, PVC Sheathed, Low-Smoke, Halogen-Free, Power Cable with Concentric Conductor WDZAN - YJY(T) - 0.6/1.0kV | 2010/06/11 --- 2013/06/10 | |
Certificate of Approval for Fire Resistance | National Supervising Test Centre for Fire Protection of Building Material Quality | Fc200950554 | WDZC - BYJ - 450/750V | 2009/11/06 --- 2012/11/05 | |
Certificate of Conformity RoHS | China Quality Certification Centre | CQC11130060964 | Lead-free Copper Polyvinyl Chloride Insulated Environmental Cable and Wires of Rated Voltages up to and including 450/750V | 2012/08/01 --- 2012/08/01 |
China Compulsory Certification | National Center for Quality Supervision & Test of Electric Wire and Cable | Cable for Railway Vehicle, WDZ - DCYJB/3 - 125 | 2012/02/16 | |
Test Report | National Center for Quality Supervision & Test of Electric Wire and Cable | Cu-Core, Low-Smoke, Halogen-Free, Flameproof Class A, Termite/Rat, Resistance, PVC Sh eathed, Copper Tape Screened Cable, WDZA - YJY63 26/35kV | 2012/02/20 | |
Test Report | China National Supervision and Test Center for Cable and Wire Production Quality (Wuhan) | per-Cored, XLPE Insulated, Creasing - Aluminum Sheathed and PVC Sheathed Power Cable, WDZA - FSY - YJY63 | 2012/02/20 |