mcb auxiliary switch: auxiliary contact, alarm contact, shunt release,mx + of, under voltage release,over voltage.

HH45/60/61 Circuit breaker univeral auxiliary switch / univeral accessory, mx + of

Scope of Application

 OF and SD are suitable for auxiliary ON/OF contact. Can point out the disconnect or put through position of the circuit breaker ,can install on left of the Circuit Breaker.SD is with indication window for alarm.For use as the sound or light signal.Be applicable to instruct coherent broken state of circuit,chassis or front or reverse side of outer shell or operations area can see the signal instruction.Can be used for uniting the warning contact,Standard:IEC40947  MX SHUNT RELEASE is suitable for telecontrol release,can install on the right of the Circuit Breaker. Be applicable to telecontrol and disconnect electric circuit,connect with fire control warning system. Telecontrol release by emergent button. Rated Voltage(Un):AC 380V \ 220V \ 127V DC:48V \ 36V \ 24VHHGQ OVER/SHORT VOLTAGE RELEASE is to help the ciucuit breaker trips automatically when voltage decline to lower or raise than setting value. To ensure automatic tripping under situation of over voltage and under voltage MN is under voltage release with loss voltage protection

Main Technical Parameters
NameRated current (A)Every groups numberof contactWiring diagram
AC 380VAC 220VDC 110V
auxiliary contact OF361One normal openOne normal close 
alarming contact SD361One normal openOne normal close
2.Technical parameters of shunt release and shunt release with auxiliary contact.
NameRatedinsulationvoltage UiRated controlpower supplyvoltage USPowerconsumption Of release(W or VA)AttractingvoltageWiringdiagram
MX+OFshunt release with auxiliary contact415VAC/DC:220380V110220V240(0.71.1) Us 
AC/DC:2448V120
HHMX+OFshuntreleasewithauxiliarycontactWithControlPowersupply415VAC/DC:220380V110220V240(0.71.1) Us 
AC/DC:2448V120
WithoutControlPowersupply415VAC/DC:220380V110220V240(0.71.1) Us 
AC/DC:2448V120
HHMXshunt release415VAC/DC:220380V110220V240(0.71.1) Us 
AC/DC:2448V120
3.Technical parameters of overvoltage,undervoltage,over-undervoltage release and loss-voltage protection device
NameRated workingvoltage UeAct voltageWiring diagram
HHGOvervoltagereleaseAC:Un=230V(over voltage)275V±5% 
HHQUndervoltageReleaseAC:230V(under voltage)(0.350.75)Ue
HHGQOver-undervoltagereleaseAC:Un=230V(over-under voltage)Overvoltage:275V±5%Undervoltage:170±7V
MNunder+lossprotection deviceAC:230V48VDC:48V(0.350.75)Ue