MGI-200W Intelligent Micro On-grid & AC To DC Inverter
System Features:
Integrated balance-of-systems components120/240-volt split-phase operation and true sine wave outputUnsurpassed surge capacity - innovative Full Digital Control regulates voltage to prevent a drop during a power surge. Full 200% rated output power is delivered to the loadEfficient, power factor corrected, high-current, multistage battery chargingEasy and inexpensive to install (does not arrive pre-assembled)Local display on inverter shows output power, charge current and battery level, to provide system status at a glanceDesigned for easy field installation with manageable building blocksParameter Table
MGI series models | SY-MGI-200W/230V |
Grid inverter working conditions | The electrical utility grid must have current and voltage is 230VAC(190~260VAC) |
Recommend use solar panels | 18V/240Wp |
DC Maximum Input Power | Automatic control |
DC maximum voltage | VpvDC28.5VDC |
DC voltage range | Vpv 10.8V~28VDC |
Maximum input current | Automatic control |
AC output power | 200W |
AC maximum output power | 240W |
Anti-voltage protection | Fuse |
AC standard voltage range | 230V(190~260VAC) |
AC frequency range | 50Hz/60Hz(Automatic detection and adjust) |
Output current total harmonic distortion | THDIAC <3% |
Phase shift rate | <1% |
Islanding protection | Vac;Fac |
Output short circuit protection | Fuse |
Show | LED |
Standby Power | <2W |
Voltage at Pmax | >15.5VDC |
Maximum output power factor | 98% |
DC TO AC Conversion efficiency | >89% |
Work temperature range | -25 °C~60°C(skin temperature) |
Temperature protection | >75°C(skin temperature) |
Humidity | 0~99%(Indoor Type Design) |
Waterproof | Indoor Type Design |
EMC | EN61000-6-3:2007 EN61000-6-1:2007 |
Grid disturbance | EN 50178+EN 62109-1+VDE0126-1-12 |
Grid detection | DIN VDE 1026 UL1741 |
certifications | CE certificate |
Notes:
---Please pay attention of the voltage when use the product. The voltage is from 10.5—28V, if is not these voltage the product may broken.
---Recommended Maximum DC input 4AWG cable capable of handling more than 50A of the cable size.
---Optimal length of the DC input line 8M or less, long cable will allow solar panels to the inverter DC voltage drop caused by wear and tear.
---Connected to a power outlet to provide AC
---Connected solar panels, battery or wind generators DC input DC power supply cable.
---Proposed wind power plant with its own charge controller and load dump.
Application for Off Grid Power systems A pure sine wave inverter can be used with off grid solar, home wind turbine or hydro power systems not connected to electric grid. You may find a pure sine inverter with a built-in AC battery charger.Pure sine wave output is best for sensitive electronic equipment such as laser printers, medical devices, and high-end electronic equipment up to 1000 watts.