Feature
1 Universal transmitter for five detection principle .Intelligent sensors applicable for hundreds kinds of gas and different detection range
completely compatible and interchangeable
2 Plug-in sensor, ease of replacement. The transmitter can automatically recognize its measuring principle or measured gases
3 Hot swap sensor, plug and play, fault diagnostics
4 Advance 32 bits MCU technology, fast data processing
5 Power by controller or individual power
6 Ultra-bright OLED and wide range temperature. the sensors are specifically designed for harsh and extreme locations
7 User friendly interface
8 Operator interface is non-intrusive via a small handheld magnet or bi-directional infrared remote
9 MT design---compact and reliable
Display | OLED(Organic Light Emitting Diode) Two level alarms and fault alarm indicator |
Operation | magnetic pen & bi-directional infrared remote controller (optional) |
Measurement | Combustible, toxic gas |
Principle | Metal Dioxide (Chemfet Mos) |
Sample Method | natural diffusion |
Measurement Range | 100ppm,200ppm,500ppm,1000ppm,2000ppm,3000ppm |
Resolution | 1%F.S |
Accuracy | 3% F.S. |
Response Time (T90) | ≤30 sec |
Alarm Configuration | two levels alarm, the alarm concentration programmable |
Ambient Temperature | (-40~70)ºC |
Ambient Humidity | ≤93%RH (no condensation) |
Atmosphere Pressure | (86~106) KPa |
Output | (4~20)mA + BUS(CAN,RS485,HART)(OPTIONAL) |
Transmission | (4~20)mA and HART≤1000m(2.5 mm2) CAN BUS≤10km RS485 BUS≤1.2km |
Power Supply | DC24V±6V power by controller or individual power |
Wiring | 2-wire 3-wire 4-wire |
Power Consumption | ≤2W |
Storage Temperature | (-40~85)ºC |
Anti–explosion Marker | ExIICT6 |
Protection Rating | IP66 |
Applicable Standard | GB15322.1-2003 |
Display | OLED(Organic Light Emitting Diode) Two level alarms and fault alarm indicator |
Operation | magnetic pen & bi-directional infrared remote controller (optional) |
Measurement | Combustible, toxic gas |
Principle | Photo Ionization |
Sample Method | natural diffusion |
Measurement Range | 20ppm,100ppm,200ppm,500ppm,1000ppm,2000ppm |
Resolution | 1%F.S |
Accuracy | 3% F.S.= |
Response Time (T90) | ≤30 sec |
Alarm Configuration | two levels alarm, the alarm concentration programmable |
Ambient Temperature | (-40~70)ºC |
Ambient Humidity | ≤93%RH (no condensation) |
Atmosphere Pressure | (86~106) KPa |
Output | (4~20)mA + BUS(CAN,RS485,HART)(OPTIONAL) |
Transmission | (4~20)mA and HART≤1000m(2.5 mm2) CAN BUS ≤10km RS485 BUS ≤1.2km |
Power Supply | DC24V±6V power by controller or individual power |
Wiring | 2-wire 3-wire 4-wire |
Power Consumption | ≤2W |
Storage Temperature | (-40~85)ºC |
Anti–explosion Marker | ExdIICT6 |
Protection Rating | IP66 |
Applicable Standard | GB15322.1-2003 |