data transceiver
Features and functions
poe PROCET PT- PSE1201-AT is a twelve ports concentrated network long-distance power supply implement. Can be installed on standard rack, can work regularly between input voltage 100VAC ~ 280VAC.This power supply use super type 5 cable to connect with network terminal equipment, suitable for 10/100 network environment.
Model | PT- PSE1201-AT |
System reliability | MTBF>100k hours |
No. of Ports | 12 Port |
Temperature | -5°C~+55°C |
Relative humidity | 5%~90%RH |
Input voltage | 100VAC~280VAC,47Hz~63Hz |
Maximum output power | 200W |
Output voltage regulation accuracy | -48VDC±2% |
Load regulation | -48VDC±1% |
Dimensions | 436(W) x44 (H) x210 (D) mm |
Weight | <4kg |
DC output voltage of broadband noise | 3.4kHz~150kHz≤50mv 0.15MHz~30MHz≤20mv |
Range of output over-voltage protection | -52VDC~-50VDC |
Over-temperature protection | >100°C |
Over-current protection(Single circuit) | 350Ma~400Ma |
Over voltage protection | Input voltage >290VAC~310VAC |
Over voltage recovery point | Input voltage > 285VAC |
Under voltage protection | <85VAC~90VAC |
Under voltage recovery point | <100VAC |
Safety Approvals | CE,RE,EN55022,CLASSB |
Discrete noise voltage
3.4KHz~150KHz≤5mv150KHz~200KHz≤3mv200KHz~500KHz≤2mv0.5MHz~30MHz≤1mv
Installation and Commissioning.1. Insert the input power line into 110--220VAC introducing input socket.
2. Connected to the output signal respectively3. Connect communicating & introducing line, signal wire, output lines tightly to avoid bad contacts and loose.
Boot Test
1.Using resistance gears of millimeter to detect Ac input, short circuit phenomena did not exit; after loading, green light in output interface is on shows output normally. If it is off after several seconds shows short circuit and limited flow phenomena did exit.2. After electric communication, the working light in front board is on.
Daily maintenance and maintenance
Long-distance power supply poe PROCET PT- PSE1201-AT can work uninterruptedly,to guarantee the reliability of the power supply, must prepare daily maintenance work, make the power system in the best working state.1. Clean power source regularly to prevent dirt retention phenomenon
2. Check whether the connecting line of input and output is loose or contact undesirable, if damaged, please change in time.
StorageWhen storing, must be kept in dry warehouse, not exposure to sun and rain.Storage temperature:-5°C~+55°C (low temperature storage recovery time is at least 4 hours)
Relative humidit: 5% ~90%RH
data transceiver12 ports