SHIELDINGS ELEMENTS
Introduction
The following solutions are offered for any kind of shielding needs.
- Shield rings
- Open tapered shield ring
- Closed, wound metallized shield rings
- Flexible core shields and yoke shields
Field of Application
Shielding elements are used to define areas of uniform electrical potential at the end of the winding,
around the magnetic core or in some cases within windings.
Types
Core shields / Yoke shields
Flexible shields provide an economical means of electrostatic shielding around magnetic cores
and inside winding structures. Moreover, centre terminal exits through the tap winding can be shielded.
Flexible shields are used in power and traction transformers. With these shields, the conductive layer is
bonded between two TRANSFORMERBOARD TIV boards under high pressure. Because of
this strong construction, the metal layer is effectively protected against mechanical damage.
Closed, wound metallized shield ring
Metallized shield rings control and smooth the electrical field at the axial winding ends of power
transformers. They generally consist of a hard core of TRANSFORMERBOARD covered with a layer of
metal-foil tape. The outer insulating layer of the metallized shield ring consists of crepe paper tightly
wrapped around the ring by machine.
Open, wound tapered end compensating ring (core wound)
Metallized shield rings control and smooth the electrical field at the helical winding ends of power
transformers. Wound, metallized tapered end rings are used for spiral windings (often regulating windings)
to compensate for axial length.