Welcome to ECOL - Join Free - Sign In
mine explosion-proof and intrinsically safe high-voltage vacuum electromagnetic actuator
mine explosion-proof and intrinsically safe high-voltage vacuum electromagnetic actuator
Supplier Info
[China Supplier]
Contact Person : Ms. Ke Carrie
Tel : 86-577-62667833
Fax : 86-577-62665883
Product Detail
Mine Explosion-proof and Intrinsically Safe High-Voltage Vacuum Electromagnetic Actuator;Rated thermal stable time 4s

 

Mine Explosion-proof and Intrinsically Safe High-Voltage Vacuum Electromagnetic Actuator

  

Applications

 The high-voltage vacuum electromagnetic actuator is suitable for control of direct starting or stopping three-phase squirrel-cage induction motor in insulated neutral or arc suppression coil grounding power supply system under the coal well with explosive gases and coal soot, with the rated voltage of 10kV, rated frequency of 50Hz and rated current of 400A. Besides, its also suitable for protection of the

motor and relevant circuit.

 

Features

1. The advanced CPU technology is adopted in the protector, which has enhanced function independence of individual parts and practicability of the system. Besides, the high-resolution A/D converter and the detection method of single measuring range are also used in the device, which has greatly enhanced the accuracy of data collection;

2. It adopts blue-backlight Chinese LCD display, which enables data display and all operations more intuitive;

3. It has the function of detection and display of the power factor and degree of imbalance between the phases as well as display of electricity consumption (active component) and real-time clock and so on;

4. It can provide protection in such cases as overload, short circuit, electricity leakage, insulation monitoring, overvoltage, undervoltage, three-phase imbalance etc.;

5. It has the RS485 communication function, which can network 2~999 protectors into the LAN or Internet with connectors.

 

Main technical parameters

Rated voltage

3.3KV6KV10KV

Maximum working voltage

3.6KV7.2KV12KV

Rated current

50A100A 200A 315A 400A

Rated frequency

5OHZ

Rated short-circuit breaking current

3.2KA

Rated short-circuit switching current

4KA

Rated thermal stable current (effective value)

4KA

Rated peak withstanding current

10KA

Rated short-time withstanding current

4KA

Rated thermal stable time

2s

Rated breaking times of the short-circuit current

25 times

Rated switching times of the short-circuit current

100 times

Rated thermal stable time

4s