Ads by Google
Scales Indicator Specifications
Sampling Frequence | 10 times per second |
Integral Nonlinearity (INL) | ±0.001%FSR |
Full Scale Differential Input | 20mV (0.5(AVDD/GAIN) = 0.5*(5v / 128)) |
Effective Number of Bits | 19.7 |
Noise-Free Bits | 17.3 |
Scale interval(E) | 1/2/5/10/20/50 |
Number of scale intervals (n) | 2000/2500/3000/4000/5000/6000/7500/12000/15000 |
Display | WI1000E/WI2000E: 6 digit LED WI1000C/WI2000C: 6 digit LCD |
Keyboard | 6 |
Communication Interface | RS232(selective) |
Power Supply | Power adapter: 5V,200mA Built-in free maintenance battery: 4V,4AH |
Operating temperature | 0~40°C |
Storage temperature | -20°C~+50°C |
Humidity | ≤85%RH |