Product characteristics
high anchoring force , like embeddedno swelling stress and small edge spacingshort installation time and quick gelationconvenient for using and no need to weigh proportionthe unused glue can be used next time , no wasteRange of application
fixing of curtain wall bracketfixing of facilities’ foundationfixing of tunnel pipefixing of acoustic celotex board and guardrail of viaductreinforcement of construction structurereinforcement of building expandinganchoring junction of steel structure and concrete structurerepairing of concrete roadTechnical parameters (used with rebar)
Screw specification | M8 | M10 | M12 | M16 | M20 | M24 | M30 |
Drilling diameter (mm) | 10 | 12 | 14 | 18 | 24 | 28 | 35 |
Drilling depth (mm) | 80 | 90 | 110 | 145 | 180 | 220 | 280 |
Failure tensile force(KN) | 18.3 | 28.0 | 42.0 | 76.0 | 118.0 | 170.0 | 272.0 |
Failure shearing force(KN) | 8.8 | 13.8 | 20.0 | 38.1 | 59.0 | 85.0 | 135.2 |
Designed tensile force(KN) | 7.7 | 12.2 | 17.8 | 33.0 | 52.0 | 75.0 | 120.0 |
Designed shearing force(KN) | 5.2 | 8.6 | 12.5 | 23.5 | 36.5 | 53.0 | 82.0 |
Holes of single glue | 60 | 37 | 22 | 10 | 5 | 3 | 1.5 |
The data is applicable to : the strength grade of concrete being C30 , the strength grade of screw being 5.8 .
Note:
Grade 2 rebar : fy=335/mm2(standard strength) ;
Concrete strength C30,fuk.cubc.150=30N/mm2,construction temperature: -5°C~40°C ;
The strength grade of base material concrete used to implant rebars should not be below C20 , and there must be a certain mass. In addition, the rebars should not be implanted in air-slaked, crackled and incompacted concrete.
Note : the data with blue background is standard yield value.