GC9310 Gas Chromatograph
GC9310 Gas Chromatograph
Supplier Info
[China Supplier]
Contact Person : Ms. He Helen
Tel : 86-021-62551292
Fax : 86-021-62581813
Product Detail
1. packed and capillary column sampler 2. FID,TCD,ECD,NPD,FPD options 3.offer different configration for different fields GC9310 Gas Chromatograph  

Display: LCD

Interface: RS232 serial interface and USB interface

Power Supply:110/220 VAC, 50-60±1Hz

Detector: FID, ECD, TCD, NPD, FPD

Column: packed column, capillary column

Workstation Version: English

Major application fields

1. Building Indoor Environment Testing (Benzene, toluene, xylene, TVOC,NMTHC)

2. Natgas, Artificial Gas, Coal-Mine Gas, LPG, Mixed Gas, High Purity Gas (Ar,He,O2,N2,CO2)

3. Food Additives & Pesticide Residue (organophosphorus, organochlorine,amino acid methyl ester )

4. Alcohol & Liquor (methanol, ethanol, ethyl acetate, ethyl butyrate, acetaldehyde)

5. Dissolved Gas (hydrogen, methane, ethane, ethylene, acetylene, carbon monoxide, carbon dioxide)

6. Petrochemical Testing and Fine Chemicals (crude oil, gasoline, essence)

Features1. GC9310 gas chromatograph control circuit using micro-processing systems and man-machine conversation menu with real-time display of all parameters, setting values and actual values.2. GC9310 gas chromatograph can be installed packed column and capillary column, with column automatic cooling, automatic rear door opening and pressure displaying functions.3. GC9310 gas chromatograph using a double stable pneumatic system, single packed column structure and a separate set of capillary shunt valve, it can be installed capillary flow, and could be installed hydrogen and air flow in different carrier gas, these separate ways can be adjusted independently.4. GC9310 gas chromatograph column with microcomputer temperature control system and excellent anti-interference, anti-temperature overshoot ability, column, sampler,TCD and capillary injector can be used for wide temperature range and high precision temperature control, the column oven temperature can be programmable to five-stage heat up. Itcan also microcomputerized the FID amplifier range and polarity selection, TCD current settings and display.5. GC9310 gas chromatograph also has a temperature limit setting, analysis time count, temperature kepting, dynamic scan the actual temperature, opens the rear door automatically when cooling the column box, power data protection.6. GC9310 gas chromatograph with self-test function, when error occus it will be automatically close the temperature controller.7. GC9310 gas chromatograph have been designed using backpressure control syatem with a stable pre-column pressure, specialised for analysis of capillary, increased capillary system stability.Capillary Sample settings shunt / no shunt are two types of flexibility to the circuit control section with automatic split / splitless. Capillary injector cleaning function with the membrane, effectively preventing the injector at high temperatures when the phenomenon of mistake peaks.8. GC9310 gas chromatograph using a digital flow control valve knob adjustment, intuitive, and good reliability.9. GC9310 gas chromatograph injector with two options: packed column sampler for packedcolumn and large-bore capillary column analysis and capillary sampler suitable for small-caliber, large-bore capillary column analysis.10. GC9310 gas chromatograph has a variety of detector options: one is installing a single hydrogen flame detector with a single amplifier signal output, and installing TCD simultaneously,the other is installing TCD and single FID.11. Rich injectors and detectors. Specificatios

TemperatureControl

Temperature Range

5°C~399°C(Incremental 1°C)

Temperature Accuracy

Better than±0.1°C(200°C)

Temperature-programmed

magnification

10

Temperature-programmed

rate set

0.1°C~40°C/min(Incremental 1°C)(200°C)

Magnification temperature time

0~655min(Incremental 1min)

Temperature object

Column box, thermal conductivity, detector, injector, capillary injector

TCD

Sensitivity

≥3000mv.ml/mg

Baseline noise

≤20μv

Baseline draft

≤50μv/30min

Gas flow rate stability

≤1%

FID

Detection limit

≤8×10-12g/s

Baseline noise

≤5×10-14A

Baseline draft

≤2×10-13A/30min

Injector,DetectorThermal conductivityTemperature Indicators

Temperature Range

5°C~399°C(Incremental 1°C)

Temperature Accuracy

Better than ±0.1°C(200°C)

  Optional Accessories

TCD (with power)                                             

FPD                                                              

NPD                                                             

FID

ECD

Top air sampler                                                

Gas generator of nitrogen, hydrogen,air & Gas purifier

Packed columns

Capillary columns                                                

Chromatograph workstation

Septum

Liner Insert

Syringe

Conversion furnace

Shunt / unshunt sampler

Plane six-way valve

Deoxidizing tube

Bubble meter

 Consumable Accessories

Item

Name and specifications   of component

1

graphite gasket   diameter 6

2

graphite gasket   diameter 3

3

nut M8x1 diameter 3.2

4

nut M12x1 diameter 6.2

5

nut M8x1 diameter 2.1

6

microsyringe   0.5,1,10μl

7

fuse 5x20mm 5A   1A 10A

8

sampling gasket   diameter 10x5( silicon rubber )

 Packing Information:

Wooden Box 800x650x570mmG.W.:80kg