1Performance parameters of LNG dispenser
1.1Main function and features
The main chassis of the dispenser is made of stainless steel for elegant, novel and brevity appearance surface as well as ease of maintenance.
Explosion proof design for reliable safety.
Human oriented design to reduce the working strength to a great extent.
Emerson cryogenic mass flow-meter adopted for superior meter performance as well as superior repeatability and calibration stability.
LNG refueling coupling and return gas coupling both are genuine imported from USA for air tight seal and long service life.
High brilliance LCD display for clearer character.
Able to preset sum or volume before refueling as well as non-quantitative refueling.
Data protection while power-off.
Able to realize communicating with station-control system.
Able to realize one pump control several dispensers for refueling at the same time by coordinating with station-control system.
1.2Main technical parameters
1.2.1Technical parameters of the complete dispenser
Working medium: liquid natural gas (liquefied natural gas)
Flow-rate range: 0~150L/min
Accuracy: +/-1.0%FS
Working pressure: 1.6MPa
Ambient temperature: -25°C~55°C
Pipeline temperature: -196°C~55°C
Measuring unit: kg
Minimum reading: 0.01kg
Single count range: 0~9999.99kg
Total count range: 0~99999999.99kg
Refuel hose: 1 inch, 4m, stainless steel hose
Gas-return hose:1/2 inch, 4m, stainless steel hose
Refueling coupling: specialized LNG refueling coupling 1 inch, JC CARTER, USA
Quick acting coupling: quick acting coupling of 1/2 inch, Macro-Tech USA
Power supply: AC220V 5A
Overall dimension: 2300*1150*750
Weight: 450kg
Explosion proof degree: ExdeibmbⅡBT4 Gb
1.2.2Technical parameters of flow-rate sensor
Flow-rate
Rated flow-rate range: 0~13600Kg/h
Maximum flow-rate: 27200Kg/h
Accuracy(liquid): 0.10%[(zero point stability/flow-rate)×100]%
Flow-rate accuracy (gas):0.50%[( zero point stability/flow-rate)×100] %
Flow-rate repeatability(liquid):0.05%[(zero point stability/flow-rate)×100]%
Flow-rate repeatability(gas):0.25%[(zero point stability/flow-rate)×100]%
Flow-rate zero point stability/flow-rate: 0.680Kg/h
Density
Accuracy(liquid): 0.0005g/cc
Accuracy(gas): 0.002g/cc
Repeatability(liquid): 0.0002g/cc
Repeatability(gas): 0.001g/cc
Range: 0~5g/cc
Temperature
Accuracy: +/-1°C~+/-0.5%°C readings
Repeatability: +/-0.2°C
Range: -240°C~204°C
Rated pressure
Flowing pipeline rated pressure: 100Ba
External shell rated pressure: 43Bar
Short time external surging pressure:57Bar
Environment influence
Procedure temperature influence: +/-0.00025% rated flow-rate/°C
Pressure influence(flow-rate):-0.0002% nominal value/Psi
Pressure influence(density): -0.000006g/cc/Psi
Explosion proof degree: ExibⅡCT1~T6
Material and Weight
Parts contact liquid: 316L
External shell: 304L
Connection box: Aluminum plated with epoxy resin.
Weight: 13.2Kg
1.2.3Technical parameters of refueling coupling
Working medium: liquid natural gas (liquefied natural gas), methane, liquid nitrogen
Max. refueling pressure: 1.72MPa
Max. working pressure: 3.45MPa
Max. sustainable pressure: 10.3MPa
Flow-rate: 189.25L/min
Weight of refueling coupling base: 1.82Kg
Weight of refueling coupling: 5.44kg
Medium temperature: -196°C~49°C
Storage temperature: -51°C~49°C
LNG dispenser