bench multimeter 21000 counts VA80 V&A multimeter
bench multimeter 21000 counts VA80 V&A multimeter
Supplier Info
[China Supplier]
Contact Person : Ms. Cheng Mary
Tel : 86-021-69521064
Fax : 86-021-69523221
Product Detail
Key Features: 21,000/51,000 count display Large VFD dual-display with high brightness True RMS AC voltage and current meas

Key Features:

21,000/51,000  count display

Large VFD dual-display with high brightness

True RMS AC voltage and current measurements, frequency up to 100kHz

12 measurement functions, including DCV/ACV, DCI/ACI, Ω, frequency/period, diode, conduction, dBm, etc.

Parameters AC+DC, AC+Hz, Readout+%, and Readout+dBm synchronously displayed

Measurement speed up to 15times/second (VA80), and 30 times/second (VA81)

DCV measurement accuracy up to 0.02%, resolution of 10µV

Measured value displayed in the form of percentage

REL measurement mode to eliminate stray reading

Calibration without uncovering

Limit function (HI/IN/LO) for fast sorting

Standard RS232C communication interface providing convenient system communication mode

Model

VA80

VA81

Test condition

The follow specifications are in slow-speed mode.Please refer to manual for other specifications.Calibration period: one yearWorking temperture & humidity: 18Ω~20Ω, ≤90%RH, and ≤70%RH(at resistance range of 5MΩand 50MΩ)Warm-up time: 30 minAcuracy: ±(reading%+range%)Temperature coefficient:+0.1×specified accuracy/°C (from 0°C~18°C or 28°C~40°C)

Rate (reading/sec)

Slow

Medium

Fast

Slow

Medium

Fast

DCV, DCI

2.5

8

15

2.5

12

30

DCV, DCI

2.5

8

15

2.5

12

30

Ω

2.5

8

15

2.5

12

30

AC+DC

0.5

1.5

3.5

0.5

1.5

3.5

AC+Hz

0.5

1.5

3

0.5

1.5

3

Freq

4

8

12

4

8

12

DC voltage

Max.reading

Resolution

Accuracy

Input impedance

Max.reading

Resolution

Accuracy

Input impedance

Range

200mV/500mV

210.00

10μV

0.03+0.02

10MΩ

210.00

10μV

0.03+0.02

10MΩ

2V/5V

2.1000

100μV

0.03+0.01

11.1MΩ

2.1000

100μV

0.03+0.01

11.1MΩ

20V/50V

21.000

1mV

0.03+0.01

10.1MΩ

21.000

1mV

0.03+0.01

10.0MΩ

200V/500V

210.00

10mV

0.03+0.01

10MΩ

210.00

10mV

0.03+0.01

10MΩ

1000V

1200.00

100mV

0.03+0.01

10MΩ

1200.00

100mV

0.03+0.01

10MΩ

DC current

Max.reading

Resolution

Accuracy

Load V/shunt Ω

Max.reading

Resolution

Accuracy

Load V/shunt Ω

Range

2mA/5mA

2.1000

0.1μA

0.1+0.010

<0.3V/100Ω

5.1000

0.1μA

0.05+0.010

<0.6V/100Ω

20mA/50mA

21.000

1μA

0.1+0.008

<0.04V/1

51.000

1μA

0.05+0.008

<0.08V/1Ω

200mA/500mA

210.00

10μA

0.1+0.008

<0.3V/1Ω

510.00

10μA

0.05+0.008

<0.8V/1Ω

2A/5A

2.1000

100μA

0.3+0.010

<0.05V/10mΩ

5.1000

100μA

0.25+0.010

<0.1V/10mΩ

20A

20.000

1mA

0.3+0.010

<0.6V/10mΩ

20.000

1mA

0.25+0.010

<0.6V/10mΩ

AC voltage

200mV

2V

20V

200V

750V

500mV

5V

50V

500V

750V

Resolution

10μV

100μV

1mV

10mV

100mV

10μV

100μV

1mV

10mV

100mV

Accuracy

20~50Hz

1.20+0.16

------

1.20+0.16

------

50~20KHz

0.5+0.1

0.4+0.05

0.8+0.08

0.4+0.06

0.35+0.02

050+0.03

20K~50KHz

2.0+0.2

1.5+0.08

1.5+0.1

1.00+0.04

50K~100KHz

5.0+0.8

5.0+0.3

3.0+0.3

3.0+0.1

AC current

2mA

20mA

200mA

2A

20A

5mA

50mA

500mA

5A

20A

Resolution

0.1μA

1μA

10μA

100μA

1mA

0.1μA

1μA...

10μA

100μA

1mA

Accuracy

20~50Hz

1.50+0.2

2.00+0.2

1.50+0.16

 

50~2KHz

0.5+0.12

0.5+0.2

------

0.5+0.08

 

------

2K~20KHz

2+0.2

2+0.15

------

2+0.16 2+0.12------

Load V/shunt Ω

The same to DC current

The same to DC current

Resistance

Max.reading

Resolution

Test current

Accuracy

Max.reading

Resolution

Test current

Accuracy

Range

200Ω/500Ω

210.00

10mΩ

0.5mA

0.10+0.02

510.00

10mΩ

0.5mA

0.10+0.010

2KΩ/5KΩ

2.1000

100mΩ

0.45mA

0.10+0.01

5.1000

100mΩ

0.45mA

0.10+0.008

20KΩ/50kΩ

21.000

45μA

0.10+0.01

51.000

45μA

0.10+0.008

200KΩ/500KΩ

210.00

10Ω

4.5μA

0.10+0.01

510.00

10Ω

4.5μA

0.10+0.008

2MΩ/5MΩ

2.1000

100Ω

450nA

0.15+0.01

5.1000

100Ω

450nA

0.15+0.008

20MΩ/50MΩ

21.000

1KΩ

45nA

0.30+0.02

51.000

1KΩ

45nA

0.3+0.010

Frequency

Max.reading

Resolution

Accuracy

Sensitivity

Max.reading

Resolution

Accuracy

Sensitivity

Range

50Hz

510.00

0.01Hz

0.05+0.02

200mV rms

510.00

0.01Hz

0.05+0.02

200mV rms

5KHz

5.1000

0.1Hz

0.01+0.02

300mV rms

5.1000

0.1Hz

0.01+0.02

300mV rms

50KHz

51.000

1Hz

0.01+0.008

300mV rms

51.000

1Hz

0.01+0.008

300mV rms

500KHz

999.99

10Hz

0.01+0.008

500mV rms

999.99

10Hz

0.01+0.008

500mV rms

bench multimeter 21000 counts VA80 V&A multimeter