Lightning conductor
Product Features:
TQYF-6.3 series lightning rod are made from stainless-steel material,it has different protection area and various features.
.Petrifaction storage, gas station, building construction, the beacon Taiwan, the communications station, observatory, military bases, the radar room, bank buildings. Reflection device have each one hole which opposite to activation device,reflection device,center collection pole connected to the earthing.The base of activation device made from polyvinyl, it's applicable to any corrupt environment.
Not electron style,life long.Keep the good performance after lightning stroked.Various protection radius.Tracing the lightning in advance and conduction it to the earth completely.It would be activated only have lightning and thunder.Artistic outline.Safety and reliable.Without maintenance.Company with full set of advanced production and testing equipment,product quality in the industry to stay ahead,have passed ISO9001-2000,CE,ROHS certification and so on.For above product, we could make it as clients' parameter.Product model and protective radius
Chart of Protective Radius
TQYF Lightning rod installation height | H = Lightning rod above the level of the protected object height (m) | ||||||||
5 | 6 | 7 | 8 | 10 | 15 | 20 | 45 | 60 | |
TQYF-3.1 Lightning rod | 22 | 22 | 23 | 23 | 25 | 25 | 25 | - | - |
TQYF-3.3 Lightning rod | 42 | 42 | 43 | 43 | 43 | 44 | 45 | - | - |
TQYF-4.3 Lightning rod | 51 | 51 | 52 | 52 | 53 | 53 | 54 | - | - |
TQYF-5.3 Lightning rod | 61 | 61 | 61 | 61 | 62 | 62 | 63 | - | - |
TQYF-6.3 Lightning rod | 70 | 70 | 70 | 70 | 71 | 71 | 72 | - | - |
TQYF Lightning rod installation height | H = Lightning rod above the level of the protected object height (m) | ||||||||
TQYF-3.1 Lightning rod | 44 | 44 | 46 | 47 | 48 | 51 | 59 | - | - |
TQYF-3.3 Lightning rod | 57 | 58 | 59 | 60 | 63 | 65 | 70 | - | - |
TQYF-4.3 Lightning rod | 68 | 69 | 69 | 70 | 73 | 74 | 79 | - | - |
TQYF-5.3 Lightning rod | 78 | 79 | 79 | 80 | 82 | 84 | 88 | - | - |
TQYF-6.3 Lightning rod | 88 | 89 | 89 | 90 | 92 | 93 | 97 | - | - |
TQYF Lightning rod installation height | H = Lightning rod above the level of the protected object height (m) | |||||||||
TQYF-3.1 Lightning rod | 50 | 50 | 52 | 52 | 55 | 59 | 74 | - | - | |
TQYF-3.3 Lightning rod | 64 | 67 | 68 | 72 | 75 | 83 | 85 | - | - | |
TQYF-4.3 Lightning rod | 76 | 78 | 79 | 82 | 85 | 92 | 94 | - | - | |
TQYF-5.3 Lightning rod | 87 | 88 | 90 | 92 | 94 | 101 | 103 | - | - | |
TQYF-6.3 Lightning rod | 97 | 99 | 100 | 102 | 104 | 110 | 112 | - | - |
Lightning conductor