Computer&instrumental cable PE insulation computer&instrumental signal cable PVC sheath,copper wire braided

Computer&instrumental cablePE insulation computer&instrumental signal cablePVC sheath,copper wire braided

Extension and compensating wire and cable used in thermocouple

1 ApplicationWithin certain range of temperature, the nominal value of thermal electro-motive force of extension and compensating wire and cable the same that the cooperating thermocouple. It connect the thermocouple to measuring instrument, the producing error from temperature change on their connecte can be compensated. Thus they may constitute general class or precision class systems of temprature measured and controlled.2 Executive standards as followO/RFDL 15--2007 Equivalent adopt GB/T 4989—94 and IEC 584-3 (1989)3 Graduated No. and name of thermocouple, type and name of extension and compensating wire,name of anode and cathode of alloy wire.

Graduated No.of thermocouple Name of thermocouple Type of wirName of wire Name of alloy wire  
Anode Cathod     
Pt,Rh10-Pt SC Cu -Cu,Ni0.6 Cu Cu,Ni0.6 
Pt,Rh13-Pt RC Cu -Cu,Ni0.6 Cu Cu,Ni0.6
 Ni,Cr-Ni,Si KCA Fe- Cu,Ni22 Fe Cu,Ni22
KCB Cu -Cu,Ni40 Cu Cu,Ni40  
KX Ni,Cr10-Ni,Si3 Ni,Cr10 Ni,Si3  
 Ni,Cr,Si-Ni,Si NC Fe- Cu,Ni18 Fe Cu,Ni18
NX Ni,Cr14,Si-Ni,Si4 Ni,Cr14,Si Ni,Si4  
 Ni,Cr-Cu,Ni EX Ni,Cr10-Cu,Ni45 Ni,Cr10 Cu,Ni45
Fe- Cu,Ni JX Fe- Cu,Ni45 Fe Cu,Ni45 
Cu -Cu,Ni TX Cu -Cu,Ni45  Cu Cu,Ni45 
Note:C-- compensating wire:X-- Extension wire.      

4 Operation characteristic4.1.The used environmental temperature of insulation and sheath material, lowest laying temperature and permitted minimum bending radius for wires and cables.

Insulation and sheath material Used environment temperature °C the lowest laying temperature °C  permitted minimum bending radius,mm 
70°CPVC,FR-PVC -30~+70 0Non-armor and non-copper  tape shield: 6 times of cable O.DArmor and copper tape shield:12 times of cable O.D 
105°CPVC,FR-PVC -25~+105 0
70°C PE or HFLS-FR-PO -40~+70 -25
105°C XLPE or HFLS-FR-XLPO -30~+105 -15
FEP -60~+200 -35

4.2.Heat-resistant class (the use of class), allowance error class and working temperature for extension and compensating wires and cables.

graduated No.of thermocou-ple Type of wire Heat-resistant class and allowance error class        
General use Heat-resistant use         
General class Precision class General class Precision class       
Code Working temperat-ure°C Code Working temperat-ure°C CodeWorking temperat- ure°C Code Workingtemperat-ure°C   
S or R SC pr RC G G(100) 0~70 0~100 GS GS(100) 0~70 0~100 0~200 
KCA G G(100) 0~70 0~100 GS GS(100) 0~70 0~100 0~200 HS 0~200
KCB G G(100) 0~70 0~100 GS GS(100) 0~70 0~100  
KX G G(100) -20~70 -20~100 GS GS(100) -20~70 -20~100-25~200 HS -25~200  
NC G G(100) 0~70 0~100 GS GS(100) 0~70 0~100 0~200 HS 0~200
NX G G(100) -20~70 -20~100 GS GS(100) -20~70 -20~100-25~200 HS -25~200  
EX G G(100) -20~70 -20~100 GS GS(100) -20~70 -20~100-25~200 HS -25~200 
JX G G(100) -20~70 -20~100 GS GS(100) -20~70 -20~100-25~200 HS -25~200 
TX G G(100) -20~70 -20~100 GS GS(100) -20~70 -20~100-25~200 HS -25~200 