Computer&instrumental cablePE insulation computer&instrumental signal cablePVC sheath,copper wire braided
Extension and compensating wire and cable used in thermocouple
1 ApplicationWithin certain range of temperature, the nominal value of thermal electro-motive force of extension and compensating wire and cable the same that the cooperating thermocouple. It connect the thermocouple to measuring instrument, the producing error from temperature change on their connecte can be compensated. Thus they may constitute general class or precision class systems of temprature measured and controlled.2 Executive standards as followO/RFDL 15--2007 Equivalent adopt GB/T 4989—94 and IEC 584-3 (1989)3 Graduated No. and name of thermocouple, type and name of extension and compensating wire,name of anode and cathode of alloy wire.
Graduated No.of thermocouple | Name of thermocouple | Type of wir | Name of wire | Name of alloy wire | |
Anode | Cathod | ||||
S | Pt,Rh10-Pt | SC | Cu -Cu,Ni0.6 | Cu | Cu,Ni0.6 |
R | Pt,Rh13-Pt | RC | Cu -Cu,Ni0.6 | Cu | Cu,Ni0.6 |
K | Ni,Cr-Ni,Si | KCA | Fe- Cu,Ni22 | Fe | Cu,Ni22 |
KCB | Cu -Cu,Ni40 | Cu | Cu,Ni40 | ||
KX | Ni,Cr10-Ni,Si3 | Ni,Cr10 | Ni,Si3 | ||
N | Ni,Cr,Si-Ni,Si | NC | Fe- Cu,Ni18 | Fe | Cu,Ni18 |
NX | Ni,Cr14,Si-Ni,Si4 | Ni,Cr14,Si | Ni,Si4 | ||
E | Ni,Cr-Cu,Ni | EX | Ni,Cr10-Cu,Ni45 | Ni,Cr10 | Cu,Ni45 |
J | Fe- Cu,Ni | JX | Fe- Cu,Ni45 | Fe | Cu,Ni45 |
T | Cu -Cu,Ni | TX | Cu -Cu,Ni45 | Cu | Cu,Ni45 |
Note:C-- compensating wire:X-- Extension wire. |
4 Operation characteristic4.1.The used environmental temperature of insulation and sheath material, lowest laying temperature and permitted minimum bending radius for wires and cables.
Insulation and sheath material | Used environment temperature °C | the lowest laying temperature °C | permitted minimum bending radius,mm |
70°CPVC,FR-PVC | -30~+70 | 0 | Non-armor and non-copper tape shield: 6 times of cable O.DArmor and copper tape shield:12 times of cable O.D |
105°CPVC,FR-PVC | -25~+105 | 0 | |
70°C PE or HFLS-FR-PO | -40~+70 | -25 | |
105°C XLPE or HFLS-FR-XLPO | -30~+105 | -15 | |
FEP | -60~+200 | -35 |
4.2.Heat-resistant class (the use of class), allowance error class and working temperature for extension and compensating wires and cables.
graduated No.of thermocou-ple | Type of wire | Heat-resistant class and allowance error class | |||||||
General use | Heat-resistant use | ||||||||
General class | Precision class | General class | Precision class | ||||||
Code | Working temperat-ure°C | Code | Working temperat-ure°C | Code | Working temperat- ure°C | Code | Workingtemperat-ure°C | ||
S or R | SC pr RC | G G(100) | 0~70 0~100 | GS GS(100) | 0~70 0~100 | H | 0~200 | - | - |
K | KCA | G G(100) | 0~70 0~100 | GS GS(100) | 0~70 0~100 | H | 0~200 | HS | 0~200 |
KCB | G G(100) | 0~70 0~100 | GS GS(100) | 0~70 0~100 | - | - | - | - | |
KX | G G(100) | -20~70 -20~100 | GS GS(100) | -20~70 -20~100 | H | -25~200 | HS | -25~200 | |
N | NC | G G(100) | 0~70 0~100 | GS GS(100) | 0~70 0~100 | H | 0~200 | HS | 0~200 |
NX | G G(100) | -20~70 -20~100 | GS GS(100) | -20~70 -20~100 | H | -25~200 | HS | -25~200 | |
E | EX | G G(100) | -20~70 -20~100 | GS GS(100) | -20~70 -20~100 | H | -25~200 | HS | -25~200 |
J | JX | G G(100) | -20~70 -20~100 | GS GS(100) | -20~70 -20~100 | H | -25~200 | HS | -25~200 |
T | TX | G G(100) | -20~70 -20~100 | GS GS(100) | -20~70 -20~100 | H | -25~200 | HS | -25~200 |
Copper Core PVC insulation and sheath collective shield computer&Instrumental signal cable