portable ultrasonic flaw detector
I. LCD Display
Active Area | W: 108 mm (4.25”) x H: 64.8 mm (2.55”) |
Size | 5.0” |
Pixel Resolution | 800 (W) x 480 (H) dot |
II. Connectors
Probe Connectors | Two LEMO-00 |
UT Output Connector | SAP output, Alarm |
USB Interface | micro USB connector |
SD-Card Connector | Full size SD card slot to accommodate standard SD cards |
III. Pulser - All pulser measurements taken according to EN12668 specifications
Pulser Mode | Simulated spike standard, Uni-polar adjustable square waveoptional |
Pulser Voltage (SQ Mode) | 120 V to 300 V with 10 V step in a tolerance of 10% |
Pulser Width (SQ Mode) | 30 ns to 500 ns with 20 ns step in a tolerance of 10% |
Pulser Amplitude (Spike Mode) | Low: 120 V, High: 300 V |
Damping | 50 or 1000 Ohms |
PRF | Automatically optimized between 15 Hz to 2000 Hz, 3 automatic adjustment modes: AutoLow, Auto Med,AutoHigh - Optional manual control of PRF from 15 to 2000 Hz including a phantom echo indicator |
IV. Receiver
Range | 14016 mm at steel longitudinal wave (557”) |
Digital Gain | Dynamic range of 110 dB, with 0.2 dB step |
Analog Bandwidth | 0.2 MHz - 20 MHz |
Filters | Broad BandLow Pass5 MHz (also 4)10 MHz13 MHz |
V. Gate
Independent Gates | 2 gates (A and B), Gate B supports triggering by gate A | ||||
Filters |
| ||||
Measurements |
|
VI. Memory
Capacity | 2 GB SD Card |
Report | Jpeg reports |
VII. Environmental
Battery | 5.5 hoursOn board chargingOff board charging with optional adaptorProportional battery gauge indicating remaining operation time |
Charger | “Universal” AC (100-240 V, 50-60 Hz)Meets CCC, CE, UL, CSA and PSE requirements |
Size | 175 mm x 111 mm x 50 mm |
Weight | 845 g (1.87 lb) with the battery |
VIII. Receiver
USM Go AWS Option | AWS sizing tool according to AWS D1.1 Structural welding code | ||||||
USM Go Dac Option |
| ||||||
USM Go DGS Option | DGS sizing tool compliant with EN 1712 | ||||||
USM Go Embedded Datalogger Option | Custom linear and grid file creation | ||||||
USM Go Squarewave Pulser Option | Allows pulser parameters fine tuningVoltage adjustment from 120 V to 300V per 10 V stepsPulse width adjustment from 30 ns to 500 ns per 10ns steps | ||||||
USM Go Manual PRF and Phantom Option | Allows Manual PRF optimization between 15 Hz and2000 Hz per step of 5 Hz. Phantom PRF will help toidentify ghost echo due to multiple reflections in lowmaterials |
IX. Languages
Russian, Portuguese, Italian, Polish, Czech, English, German, French, Spanish, Chinese and Japanese