Hot water heat pump has the follwoing features:
1.Steel metal parts made of galvanized powder coated steel.2.Use the special compressor for heat pump water heater.3.Highest setting water temperature is 55°C .4.Green Refrigerant: R407c.5.Thermostatic expansion valve regulates flow of refrigerant precisely.6.Freely set openning cycle time in advance.7.Automatic defrost and auto-adjusting according to defferent condition.8.Units can automatic prevent freezing in the winter.
Model | Unit | PW030-KFXLR | PW040-KFXLR | PW050-KFXLR | PW060-KFXLR | |
Heating Capacity | kW | 10.8 | 14.4 | 18 | 21.6 | |
Power Input | kW | 2.7 | 3.6 | 4.5 | 5.4 | |
Rated Current | A | 12.2 | 16.2 | 20.25 | 10.8 | |
Largest Input | kW | 3.6 | 4.9 | 6.1 | 7.3 | |
Largest Current | A | 16.2 | 21.6 | 27 | 14.4 | |
Rated Water Temp. | °C | 55 | 55 | 55 | 55 | |
Highest Water Temp. | °C | 60 | 60 | 60 | 60 | |
Power Supply | 220V/1P/50Hz | 380V/3P/50Hz | ||||
Anti-electric Shock Type | I | I | I | I | ||
Compressor |
| Rotary | Scroll | |||
Quantity of Compressor |
| 1 | 1 | 1 | 1 | |
Fan Direction |
| Side | ||||
Fan Power Input | W | 150 | 230 | 330 | 150*2 | |
Fan Rotate Speed | RPM | 900 | 920 | 910 | 900 | |
Refrigerant |
| R407c | R407c | R407c | R407c | |
Ambient temp. | °C | -55 | -55 | -55 | -55 | |
Hot Water Supply | L/H | 232 | 310 | 387 | 464 | |
Pipe Size | Inch | 1″ | 1″ | 1″ | 1″ | |
Circulation of Water Capacity | M3/h | 3 | 4 | 5 | 6 | |
Pressure from Tap Water | kPa | 46 | 46 | 46 | 46 | |
Noise | dBA | ≤54 | ≤54 | ≤56 | ≤56 | |
Mainframe Weight | kg | 100 | 130 | 180 | 200 | |
Dimension | L*W*H | mm | 1110*425*615 | 1110*425*815 | 1180*425*965 | 1110*425*1225 |
Running conditions: Ambinet temperature DB(dry bulb) 20 °C,WB(wet bulb)15°C,water input at 15°C. |
money-saving Heat pump water heater