Ads by Google
DC INVERTER R410A AIR TO WATER 20KW (split type)
Inside unit include: LCD controller, three way valve, flow switch, WILO water pump, plate heat Exchanger and inside connectionOutside unit with DC inverter R410a, electrical expansion valve, compressor heater, bottom heater. with remote control function. With different control languageSpecification
Indoor unit
Model | KS200-DC | ||
Function | Heating only | ||
Dimensions | WxHxD | mm | 600X730X400 |
Weight | kg | 50 | |
Leaving water temperature range | heating | °C | 20-60 |
cooling | °C | 5-35 | |
Hot water | °C | 20-60 | |
Water three way valve | Yes | ||
Heat exchanger | Stainless steel plate | ||
Water pump | Yes | ||
Shell material | Epoxy polyester painted galvanised steel | ||
Additional electrical heater | KW | (a)3kw--0nly one piece E-heater; (230V/50Hz/1Ph) (b)3kwX3=9kw--Three pcs E heater ( 400V/50Hz/3Ph or 230V/50Hz/3Ph) | |
Power supply | V/Hz/Ph | *230/50/1 *230/50/3 *400/50/3 |
* Standard model is heating only.Cooling and heating is optional
Outdoor unit
Model | KS250-DC | ||
Dimensions | WxHxD | mm | 1110x1850x425 |
Nominal Capacity | heating | kW | 19.78 |
cooling | kW | 18.1 | |
Nominal input | heating | kW | 4.98 |
cooling | kW | 6.5 | |
COP | 3.97 | ||
EER | 2.78 | ||
Compressor | type | Scroll | |
Quantity | 2 (one is on/off type, Another is inverter) | ||
Brand | Hitachi | ||
Operation ambient range | °C | -20- 43 | |
Sound pressure level | heating | dBA | 58 |
cooling | dBA | 60 | |
Weight | kg | 205 | |
Refrigerant charge | R-410A | kg | 5.3 |
Power supply * optional | V/Hz/Ph | *230/50/3 *400/50/3 |
* Measurement condition:A7/W35 (heating mode), A35/W7 (cooling mode).
Get more details please contact our Website or Company.
Durable Air To Water DC INVERTER Heat Pump 20KW (split type)