All-welded plate heat exchanger
The crisscross of two plates is 180 degree. All plates are welded together, and exchanger heat through two short sides of each plate. As its gasket material utilizes the metal materials, so the medium temperature ≤400, pressure ≤ 3.0 MPa. It expands the range of work, and also prolong the usage of cycle. What’s more, reduce the expense of maintenance.
HBR Dimension (Unit mm)
HBR0.12 | HBR0.23 | HBR0.46 | HBR0.52 | HBR0.72 | HBR01.2 | HBR1.4 | |
H | ≈1170 | ≈1500 | ≈3350 | ≈2260 | ≈2450 | ≈30000 | ≈6080 |
a | 270 | 310 | 370 | 424 | 630 | 630 | 1210 |
b | 820 | 1100 | 1360 | 1580 | 1750 | 2200 | 3085 |
c | 330 | 380 | 460 | 540 | 730 | 730 | 1130 |
d | Φ18 | Φ18 | Φ18 | Φ24 | Φ24 | Φ24 | Φ30 |
HBR series technical parameter
Item | Type Unit | HBR0.12 | HBR0.23 | HBR0.46 | HBR0.52 | HBR0.72 | HBR1.2 | HBR1.4 |
Transfer area | m2 | 0.12 | 0.23 | 0.46 | 0.52 | 0.72 | 1.2 | 1.4 |
Design Pressure | MPa | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 |
Design Temp | °C | 300 | 300 | 300 | 300 | 300 | 300 | 300 |
Max flow rate of hot side | Gas m3/h | 6000 | 7500 | 9000 | 26000 | 38500 | 56000 | 95000 |
Liquid m3/h | 560 | 720 | 880 | 2300 | 3600 | 5100 | 7300 | |
Max flow rate of cold side | water | 90 | 400 |
|
| 880 |
|
|
Max latus rectum of hot side | mm | 200 | 250 | 250 | 250 | 500 | 600 | 800 |
Max latus rectum of cold side | mm | 80 |
|
| 80~250 |
|
|
|
Max assembly area | m2 | 30 | 100 | 100 | 160 | 600 | 770 | 900 |
Plate thickness | mm | 0.7 0.8 0.9 1.0 | ||||||
Plate Material | SUS304 SUS316L Ti |
All-welded plate heat exchanger