Medical sugical tourniquet Radial Artery Compression Device Transplarent soft cushion Visible adjustable pressure

Medical sugical tourniquet Radial Artery Compression Device

1. Patent design for oppress the puncture point for vitro bleeding stanching after radial artery puncture.

2. Stop bleeding by simply adjusting the band or turncap.

3. Color marker helps medical staff distinguish the pressure thus makes bleeding point comfort.

4. Special material, latex free, transparent, soft and not adhesive to the skin so that medical staff can operate precisely, and control bleeding effectively.

Model:

010211      

 Description:

T1 Type, used for wrist circumferences are between 140mm to 240mm.

Pressure ref:

Green = 100mmhg-150mmhg

Yellow = 150mmhg-200mmhg

packing:

1. Individual package, 10pcs/bx, 100pcs/CTN2. Size: 64*39*24(cm/CTN)3. G.W.: 6Kg/CTN 

 Instruction:

1. After the punctural operation is completed,pull the sheath out for 2-3cm; in the meantime; make sure no vasospasm occurs.If vasospasm is evident ,it  should be treated before the hemostasis procedure begins.

2.Align the front edge of the compression pad with puncture point ,then apply the device to patient.

3.Insert the Velcro band into strap slot on the wrist plate ,keep the top of  the  pressure indicator leveled with turn cap,affix the Velcro band firmly.

4.Rotate the turn cap following the allow indicating direction, tighten the turn  cap clockwise by three to five laps, the green pressure zone (100-200mmHg) represent safe pressure area ;if the indicator  is over the midline of the green zone, the pressure indicates approximately 150mmHg; keep rotating to yellow pressure 200-250mmHg,it suggests excessive pressure, then the device will lock up for protection from tissue damage.

5.When removing the sheath,compress both ends of wrist plate to yield   a small space allowing the sheath to be pulled out  without damaging the tissues, the pressure should be referred to the position of the green pressure indicator.

6.After appropriate time ,decompress the device by turning turn cap 1/2 to 1 full counter -clockwise circle every 45mins to 1 hour.If the bleeding re-occurs, apply compression until haemostasis is achieved and repeat above steps.

7.When haemostats is completed,rotating the turn cap counter clockwise,remove the tourniquet confirm no bleeding on the puncture  site and cover the puncture site with dressing.