Fetal Monitor/Fetal Heart Monitor /Heart rate monitor/ fetal doppler
Features:
Folded 12.1-inch TFT LCD high-brightness screen with a wide viewing angle and large numerics 12 elements / 1 MHz water proof pulse Doppler transducer for accurate detection Event marker for easy documentation of events and kick counts Fetal Movement Profile (FMP) detects and automatically records gross fetal body movements On-screen scrolling for viewing stored fetal traces Twin ultrasound monitoring capability Configurable audible and flashing fetal heart rate alarms Twin signal overlap alarm function Built-in high speed thermal printer, printing width can be set to 112mm,150mm and 210mm 24-hours memory for fetal traces Supporting TCP/IP or wireless connection to the central monitoring station Internal Li-ion battery power or AC power from external power supplyTechnical Specifications | ||||
Ultrasound (FHR) | Measurement range | US | 50 to 240 bpm | |
Resolution | Display | 1bpm | ||
Printer | 1bpm | |||
jitter@200 bpm | ≤3bpm | |||
Display update rate | 0.25second | |||
Beat to bea change(max.) for ultrasound | 28bpm | |||
US frequency | 1MHz±5%Hz | |||
TOCO | Measurement method | Strain gauge sensor element | ||
Sensitivity | 1 unit =2.5g | |||
Resolution | 1 unit | |||
Measurement range | 500 units | |||
Baseline setting | 0, 5,10, 15, 20 can be selective | |||
Update rate | 0.25 second | |||
Auto offset correction | 3 second after connecting the transducer | |||
Auto zero adjust
| TOCO value is set to zero negative following a negative Measure value for 5 seconds | |||
Auto Fetal Movement (AFM) | Technique | Pulsed doppler ultrasound | ||
Range | 0-100% | |||
Resolution | 1% | |||
Automatic fetal movement actograph | ||||
Manual fetal movement mark | ||||
NIBP | Operation mode | Manual/automatic/ STAT | ||
Measurement unit | mmHg / kPa selectable | |||
Test interval | 0-480 minutes | |||
Accuracy | Max.Std.deviation:8 mmHg(1.1kPa) | |||
Max. mean Error: ±5mmHg(±0.7kPa) | ||||
Measurement range | Systolic | 30 to 270 mmHg(4 to 36 kPa) | ||
Diastolic | 10 to 245 mmHg(1.5 to 32kPa) | |||
Mean | 20 to 255 mmHg(2.5 to 34kPa) | |||
Pulse rate range | 40~240bpm | |||
Over-pressure protection | Yes | |||
Maternal ECG (MECG) | Heart rate range | 30~300bpm | ||
Resolution | 1bpm | |||
Accuracy | ±1bpm/ ±1% | |||
Leads | I, II, III, avL, avR, avF, V | |||
Sweep speed | 12.5mm/s, 25mm/s, 50mm/s | |||
Gain selection | x 0.25, x0.5 ,x1,1, x2 | |||
Operation mode | diagnostic, monitor, surgery | |||
Maternal SpO2 (MSpO2) | Measurement range | 0%-100% | ||
Resolution | 1% | |||
Accuracy | ±2% | |||
Pulse rate range accuracy | ±3bpm | |||
Temperature (TEMP) | Technique | Thermistor probe CYSI 400 series compatible | ||
Measurement range | 0c-50c | |||
Accuracy | ±0.1c |
Fetal Monitor