Main technical specification of 240kw natural gas generator
Model Number | 300GFT |
Brand Name | JiaSheng |
Prime power/Standby power | 240KW |
Rated Speed | 1000RPM |
Rated Frequency | 50/60Hz |
Rated Voltage | 400V/230V |
Phase | AC 3-Phase, 4 wire |
Voltage Stability | ≤±2% |
Voltage transient | ≤±10% |
Voltage Stable time | ≤1s |
Heat consumption | ≤9.8mj/kw.h |
Lubricant consumption | ≤0.3 m3 |
Cylinder Number | 6 |
Cylinder Bore | 190mm |
Stroke | 210mm |
Starting System | DC 24V electric motor |
Cooling method | water cooling(closed/open) |
Lubricant method | Passive and flying lubricant |
Isolation class | H |
Protection | IP21 |
Alternator | Siemens |
Power Factor | 0.8 lagging |
Exciting method | brushless |
Certificates | ISO 9001:2008, CE |
Type | Open |
Control system | Automatic alarm system |
Detailed Product Description Standard Configuration of Natural Gas Generating Set: Engine: 1,water cooling , 4 stroke 2,ratiation with water tank & fan & safe guard Alternator:Stamford/Marathon (Made in China ) 1,single bearing,4pole and self excited brushless. 2,insulation --H class,Protection -- IP22 (IP23 in marine) 3,AVR(auto voltage regulation) Control System: Key starting,Auto control panel,Remote control panel,ATS(Auto transfer switch) D.G.set Performence of Natural Gas Generating Set: 1) Water cooled inside --closed circle water cooling system. 2) Compressed air to start. 3) Standard voltage is 400/230V and the rated frquency 50HZ,with R.P.M 1500 ,3pha & 4wire contected.(60HZ can be provided according to your special requests..) 4) Completed parameter display ,all in english languge,with perfect protection and control function.low water alarm,high gas temperature, low oil pressure and high water temprature protection alarm are all installed... 6) Independantly over-load protection ,automatically emergency stop in abnormal situation,unique sensors protection,adapt to all sensors... 7) Stainless steel base with vibration pad.blue color,package :plastic wraped or wooden case. 8) Noise-proof,exhaust silencer... 9) Documents can be submited:installation & maitenance instruction,operation's manual,quality certificate and ex-factory testing report ... Requirements to Natural gas: Thermal Value 41860 KJ/m3, CH4 >=85% (By Volume), S<=460 mg/m3, H2S <= 20 mg/m3 Gas Pressure: 80--200kpa (mounded by pressure-reduced separated surge tank) Gas should be exact dry after processed and dirty mixed on the gas should be less than 0.005 mm, dirty contents should be not larger than 0.03 mg/m3, Standard condition of natural gas volumes must be 101.3 kpa, 20 Optional of Natural Gas Generating Set: exhaust pipe,flexible pipe,muffler,charge battery,daily used fuel oil tank and so on ...