SP-3400 Gas Chromatography
SP-3400 Gas Chromatography
Supplier Info
[China Supplier]
Contact Person : Mr. Linda Ding
Tel : 86-10-62023948
Fax : 86-10-62016954
Product Detail
It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology, scientific research, etc.

APPLICATIONS

SP-3400 Gas Chromatograph, made according to international standards, its technical feature and index are in the world high level. The key components are imported from world famous suppliers. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology, scientific research, etc.

FEATURES

Ÿ Self-diagnostic function

1) Core tests

2) Automatic tests

3) Extended tests

4) Basic tests

Monitor the status of GC continuously. Once finding faults, it’ll display the information and show the wrong zone and the settling method.

Ÿ Self-protective function

1) Overrun temperature protection

2) Short circuit hint

3) TCD filament protection

4) FID flameout hint

5) PFD exposed-light protection

6) Keyboard locking with password

etc., ensuring normal running.

Ÿ Simple operation, powerful automation

1) All parameters can be entered through keyboard with prompt function

2) 4 sets of complete chromatography analysis methods can be stored and recalled automatically

3) An autosampler can be connected

4) Parameters can be modified instantly while the GC is running

5) Chromatography analysis method can be activated for 99 times repeatedly at the same time. It’s especially suitable for unattended operation.

Ÿ More choices of injectors

1) On- Column Injector for Packed Column

2) Flash Vaporization Injector for Packed Column

3) Automatic or manual gas inject valve

4) Headspace sampler

5) Thermal desorption system

6) Split/Splitless Capillary Injector

Three Injectors or two Split/Splitless Capillary Injectors can be fixed on GC.

Ÿ More choices of detectors

1) TCD

2) FID

3) ECD

4) FPD

5) TSD

Maximum of two TCDs or three different kinds of detectors can be installed.

Ÿ Reactor

1) Internal

2) external

Ÿ Time programming of detectors

Each of detectors has 5-ramp programmable time control. Output-signal, attenuation range, and polarity can be set automatically.

Ÿ Time programming of external events

Providing 4 external events with 20-ramp programmable time control. The optional GC relays may be used to automate valves, operate split/splitless capillary injectors, drive auxiliary devices, or switch signals between detector A and detector B in a run.

Ÿ Many kind of special-purpose GC can be provided according to user’s request.

SPECIFICATIONS

Ÿ Column oven

Operating temperature range ambient temperature to 420°C

Dual opening-door at the back of column oven

Cooling time 250°Cto 50°Cin 5 min

Programmable oven with 4-ramp temperature control

Temperature programming rate 0.1~50°C/min

Ÿ Injector system

Operating temperature range: ambient temperature to 420°C

Ÿ Thermal conductivity detector -TCD

Maximum temperature   420°C

Sensitivity  ≥12000mv • mL/mg (for butane)

Linear range  105

Current range  50 to 400mA

Ÿ Filament protection

If He or H2 carrier gas flow in the detector cell is cut off for 4 minutes, filament power will be shut off automatically.

Ÿ Flame ionization detector-FID

Maximum temperature 420°C

Minimum detectivity ≤1.3×10-12g/s (n-C16)

Linear range  107

Flameout hint

   monitoring the status of GC continuously after being turned on.

Ÿ Electron capture detector-ECD

Maximum temperature: 420°C

Minimum detectivity

≤0.1pg/mL (γ-666)

Linear range  104

Emission source: 11mC63Ni

Ÿ Flame photometric detector-FPD

Maximum temperature 420°C

Minimum detectivity

[P] ≤1×10-12g/s (tributyl phosphate)

[S] ≤1×10-10g/s (p-methylsulfurphosoharous)

Linear range

[P]105

[S]103

Two air-hydrogen flames For large volume injection or trace sample injection analyses

Single air-hydrogen flame sulfur sensitivity can be increased

Direct output  for phosphorus or sulfur analyses

Square-root output  for sulfur analyses

Exposed-light protection

When exposed-light current is more than 12μA, high voltage will be cut off automatically.

Ÿ Nitrogen-phosphorus detector-TSD

Maximum temperature: 420°C

Minimum detectivity

[N] ≤1×10-13g/s (azobenzene)

[P] ≤5×10-14g/s (malathion)

Linear range

[N]105

[P]104

SP-3400 Gas Chromatography