Welcome to ECOL - Join Free - Sign In
G2/110 Separation Membrane Permeability Analyzer
G2/110 Separation Membrane Permeability Analyzer
Supplier Info
[China Supplier]
Contact Person : Ms. Wu Emily
Tel : 86-531-85060139
Fax : 86-531-85062108
Product Detail
G2/110 Separation Membrane Permeability Analyzer 1.Based on differential pressure method 2.Automatic temperature control

G2/110 Separation Membrane Permeability Analyzer  is based on the combination of differential pressure method and chromatography analysis technology. It is the only instrument in the market so far that provides the quantitative and qualitative analysis of gas permeability of sole gas or mixed gases in separation membranes.

Automatic temperature control system gives heating and cooling functions that tests can be carried out at any temperature within the given rangeMajor components are imported from renowned countries with stable and reliable performanceAll test parameters can be set flexibly for convenient operationWide range of power input ensures the instrument working regularly at various conditions

Applications

G2/110 Separation Membrane Permeability Analyzer  is applicable to the determination of:

PermeanceSelectivityTransmission Rate
Test the permeance of separation membranes to various components of sole gas or mixed gases under a certain condition
Test the selectivity of separation membranes to various components of mixed gases under a certain condition
Test the transmission rate of separation membranes to various components of sole gas or mixed gases under a certain condition

Technical Specifications

SpecificationsFilm TestTest RangeTest MethodTest SensitivitySpecimen ThicknessTest AreaTemperature Range of Test ChamberTemperature AccuracyTemperature Range of Test Gas PipelineTemperature AccuracyTest GasDifferential Pressure of Test GasVacuum DegreeCarrier GasCarrier Gas PressureInstrument SizePower SupplyGas ChromatographNet Weight
10-5~10-14cm3(S.T.R)·film thickness/cm2·Sec·cmHg
TCD sensor and Chromatographic standard curve method
More than 3000mv.mL/mg (for H2 and benzene)
<1 mm
3.14 cm2(Φ20 mm)
15°C~55°C
±0.1°C
5°C~100°C (ambient temperature)
±0.1°C
Test gas could be one of air, O2, N2, CO, CO2, and CH4 or their mixed gases (customization is available for other test gases ; gas resource is not in supply scope)
-0.1MPa~+0.1MPa
<20 Pa
Helium
0~0.5MPa
690mm(L) x 350mm(W) x 380mm(H)
AC (85~264)V (47~63)Hz
2500W
67kg