Ads by Google
Flow Sensor MR168
Specification:
NO. | Items | Parameter | Remarks |
1 | Body material | Nylon fiberglass | |
2 | Precision | (2-30L/min)±10% | |
3 | Voltage rating | DC=5V | |
4 | Withstand hydraulic pressure | ≤1.75MPa | |
5 | Operation voltage rating | DC5V-24V | Optional |
6 | Insulation resistance | >100mΩ | |
7 | Flow pulse(Formula) | F=(7.8Q-3) | Q:quantity L/min F:frequency Hz |
8 | Max output pulse voltage | >DC4.7V(input voltage DC 5V) | |
9 | Min output pulse voltage | <DC0.5V(input voltage DC 5V) | |
10 | Output pulse duty cycle | 50%±10% |
12. Interface size: G1/2″or(dia.19mm)
MR168 water level flow sensor/ liquid switch G1/2 DC5-24V